The DOI matches its Crossref record.
Radiofrequency Catheter Ablation: The Effect of Electrode Size on Lesion Volume In Vivo
Abstract
Radiofrequency current is a promising alternative to high voltage direct current defibrillator discharges for catheter ablation of arrhythmias. However, lesions produced with radiofrequency current are relatively small and use of high power is limited by the impedance rise that occurs with desiccation of tissue and coagulum formation. The effect of electrode size on radiofrequency ablation was assessed by comparing results of radiofrequency application using a standard 6 French electrode catheter (distal electrode 2 mm in length) to those using catheters modified with longer distal electrodes (3, 4, 6, 8, and 10 mm in length). Radiofrequency ablation was performed at 47 left ventricular endocardial sites in 20 anesthetized dogs. A constant power of 13.3 ± 1.3 watts at 550 kHz was applied between the distal catheter electrode and a skin electrode until a total of 500 joules had been delivered or a rise in impedance occurred. Increasing electrode length from 2 to 4 mm more than doubled lesion volume from a mean of 143 to 326 mm 3 (P = 0.025). Increasing electrode length beyond 4 mm produced progressively smaller lesions (157 mm 3, 155 mm 3, and 67 mm 3 for 6‐, 8‐, and 10‐mm electrode lengths, respectively). Impedance rise was significantly less likely with larger electrodes and took longer to occur. Increasing the size of electrodes used for radiofrequency ablation allows application of higher power without an impedance rise. Optimizing electrode size (3 or 4 mm in this study) results in larger lesions and may improve the effectiveness of radiofrequency ablation of arrhythmias.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nakagawa, H., Yamanashi, W. S., Pitha, J. V., Arruda, M., Wang, X., Ohtomo, K., Beckman, K. J., McClelland, J. H., Lazzara, R., & Jackman, W. M. (1995) · Circulation · doi:10.1161/01.cir.91.8.2264 · Cited by 625
Radiofrequency Ablation of Atrial Flutter: A Randomized Controlled Trial of Two Anatomic Approaches
Passman, R. S., Kadish, A. H., Dibs, S. R., Engelstein, E. D., & Goldberger, J. J. (2004) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2004.00390.x · Cited by 24
Metadata
- Authors
- LANGBERG, J. J., LEE, M. A., CHIN, M. C., & ROSENQVIST, M.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1990-10
- Volume
- 13
- Issue
- 10
- Pages
- 1242-1248
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2054824481
- Cited by
- 159
- References
- 0
- FWCI
- 11.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radiofrequency Catheter Ablation: The Effect of Electrode Size on Lesion Volume In Vivo. https://app.cochat.ai/papers/10.1111/j.1540-8159.1990.tb02022.x
- The paper
- LANGBERG, J. J., LEE, M. A., CHIN, M. C., & ROSENQVIST, M. (1990). Radiofrequency Catheter Ablation: The Effect of Electrode Size on Lesion Volume In Vivo. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1990.tb02022.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.