Permanent Pacemaker Placement in Chronic Atrial Fibrillation Associated with Intermittent AV Block and Cerebral Symptoms
The DOI matches its Crossref record.
Abstract
We examined the hypothesis that a ≥2 second pause detected on 24‐hour Holter monitoring in patients with persistent atrial fibrillation and complaints of syncope or dizziness lacked sufficient specificity to warrant implantation of a permanent pacemaker. We retrospectively reviewed cases from our 24‐hour electrocardiographic (Holter) monitoring data base. A total of 411 consecutive Holter monitoring records demonstrating persistent atrial jibrillation obtained during a 5‐year period (1982 to 1987) were examined. One hundred and five (26%) patients had cerebral symptoms (dizziness or syncope) as a primary indication for monitoring 80 (76%) patients were identified with documented ventricular pauses of ≥2 seconds. Three hundred and six patients (74%) underwent 24‐hour monitoring without cerebral symptoms as an indication and 209 (68%) patients had ≥2‐second pauses. Clinical information was available in 164 (50 symptomatic and 114 asymptomatic) patients. There were no significant differences in the clinical or Holter findings between the two groups. Of the 50 symptomatic patients, 15 (30%) underwent permanent pacemaker placement and the remaining 35 (70%) were managed conservatively during a mean follow‐up of 23 ± 5 months. Eleven of 15 paced (73%) and 31 of 35 (89%) nonpaced patients experienced resolution of their cerebral symptoms (NS). The sensitivity of Holter monitoring in detecting pauses of ≥2 seconds in patients with cerebral symptoms was high (76%), but the specificity (32%) and positive predictive values (28%) were low. In conclusion, the finding of a 2‐second pause interval on Holter monitoring lacks sufficient specificity to identify symptomatic patients with persistent atrial fibrillation. In addition, there is a high rate of spontaneous resolution of cerebral symptoms in this group without the use of a pacemaker. These findings suggest that in patients with persistent atrial fibrillation in the presence of a 2‐second pause on a Holter recording, a clear association between cerebral symptom and the pause interval is necessary before the use of a permanent pacemaker is recommended.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 5
- 10.1016/0002-9149(76)90507-5 · DOI
- 10.1378/chest.77.6.722 · DOI
- 10.1111/j.1540-8159.1983.tb05294.x · DOI · Paper page
- 10.1111/j.1540-8159.1982.tb02277.x · doi:10.1111/j.1540-8159.1982.tb02277.x
- 10.1111/j.1540-8159.1987.tb04963.x · DOI
Cited by
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000628 · Cited by 603
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.043 · Cited by 337
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000627 · Cited by 160
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2018.10.037 · Cited by 131
Metadata
- Authors
- SAXON, L. A., ALBERT, B. H., URETZ, E. F., & DENES, P.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1990-06
- Volume
- 13
- Issue
- 6
- Pages
- 724-729
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W1972234732
- Cited by
- 15
- References
- 0
- FWCI
- 0.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Permanent Pacemaker Placement in Chronic Atrial Fibrillation Associated with Intermittent AV Block and Cerebral Symptoms. https://app.cochat.ai/papers/10.1111/j.1540-8159.1990.tb02098.x
- The paper
- SAXON, L. A., ALBERT, B. H., URETZ, E. F., & DENES, P. (1990). Permanent Pacemaker Placement in Chronic Atrial Fibrillation Associated with Intermittent AV Block and Cerebral Symptoms. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1990.tb02098.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.