Reproducibility of Head Upright Tilt Table Test Results in Patients with Syncope
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Head upright tilt table testing is a promising technique for the evaluation and management of vasovagal (neuroregulatory) syncope. In order to determine the day-to-day reproducibility of results using this technique we performed head upright tilt table testing (with or without graded isoproterenol infusion) in 21 patients (12 males, 9 females, mean age 34 +/- 19.1 years). During the first tilt study a total of 14 patients experienced syncope (six during baseline tilt, mean tilt time 15.8 +/- 7 minutes, eight following tilt with graded isoproterenol infusion, mean tilt time 17.7 +/- 9 minutes) while seven were negative. During the second tilt study (performed 3-7 days following the first study) the results of the first study were duplicated in 19 patients (90%) (six during baseline tilt, mean time 17.5 +/- 8 minutes, eight following graded isoproterenol infusion, mean time 15.9 +/- 7 minutes), however the level of provocation required to provoke syncope differed from that needed in the initial test in five patients (24%). We conclude that the results of head upright tilt table testing with graded isoproterenol infusions can be duplicated in 90% of patients, although some day-to-day variability exists in the degree of provocation necessary to elicit a positive response.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluation and outcome of emergency room patients with transient loss of consciousness
Day, S. C., Cook, E. F., Funkenstein, H., & Goldman, L. (1982) · The American Journal of Medicine · doi:10.1016/0002-9343(82)90913-5 · Cited by 587
Cited by
Guidelines on management (diagnosis and treatment) of syncope
Brignole, M. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2739 · Cited by 951
Guidelines on Management (diagnosis and treatment) of syncope ? update 2004
(2004) · Europace · doi:10.1016/j.eupc.2004.08.008 · Cited by 652
Tilt table testing for assessing syncope
Benditt, D. G., Ferguson, D. W., Grubb, B. P., Kapoor, W. N., Kugler, J., Lerman, B. B., Maloney, J. D., Ravielle, A., Ross, B., Sutton, R., et al. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(96)00236-7 · Cited by 568
Self-citationThe Relationship Between Neurally Mediated Hypotension and the Chronic Fatigue Syndrome
Bou-Holaigah, I. (1995) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1995.03530120053041 · Cited by 384
Di Girolamo, E., Di Iorio, C., Sabatini, P., Leonzio, L., Barbone, C., & Barsotti, A. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00694-9 · Cited by 322
Metadata
- Authors
- GRUBB, B. P., WOLFE, D., TEMESY-ARMOS, P., HAHN, H., & ELLIOTT, L.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1992-10
- Volume
- 15
- Issue
- 10
- Pages
- 1477-1481
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2075840662
- Cited by
- 114
- References
- 1
- FWCI
- 9.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reproducibility of Head Upright Tilt Table Test Results in Patients with Syncope. https://app.cochat.ai/papers/10.1111/j.1540-8159.1992.tb02921.x
- The paper
- GRUBB, B. P., WOLFE, D., TEMESY-ARMOS, P., HAHN, H., & ELLIOTT, L. (1992). Reproducibility of Head Upright Tilt Table Test Results in Patients with Syncope. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1992.tb02921.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.