CoChat

A Double‐Blind Study of Submaximal Exercise Tolerance and Variation in Paced Rate in Atrial Synchronous Compared to Activity Sensor Modulated Ventricular Pacing

LINDE‐EDELSTAM, CECILIA, NORDLANDER, ROLF, PEHRSSON, S. KENNETH, RYDEN, LARS · 1992 · Pacing and Clinical Electrophysiology
Cited by 39

The DOI matches its Crossref record.

Abstract

To assess the variation in paced rate during everyday activity and the importance of atrioventricular synchronization (AV synchrony) for submaximal exercise tolerance, atrial synchronous (DDD) and activity rate modulated ventricular (VVI,R) pacing were compared in 17 patients with high degree AV block. The patients were randomly assigned to either mode and evaluated by treadmill exercise to moderate exertion and by 24‐hour Holter monitoring after 2 months in the DDD and VVI,R modes, respectively. At the end of the study, the patients were programmed to the pacing mode corresponding to the preferred study period. During the treadmill test, the mean exercise time to submaximal exertion (Borg 5/10), exertion ratings and respiratory rate did not differ between pacing modes despite a significantly lower ventricular rate in the VVI,R mode. The atrial rate during VVI,R pacing was significantly higher than the ventricular rate, but did not differ from the ventricular rate during DDD pacing. There was a diurnal variation in paced rate in both pacing modes. Paced ventricular rate was, however, higher and variation in paced rate greater in DDD compared to VVI,R pacing. Nine patients preferred the DDD mode, three patients preferred the VVI,R mode, while five subjects did not express any preference. The results from this study indicate that the variation in paced rate during activity sensor‐driven VVI,R pacing does not match that during DDD pacing neither during everyday activities nor during submaximal treadmill exercise, Nevertheless, no differences in exercise time, Borg ratings, and respiratory rate during submaximal exercise were found. Thus, for most patients with high degree AV block, DDD and VVI,R pacing seem equally satisfactory for submaximal exercise.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.1992.tb03081.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 39

Metadata

Authors
LINDE‐EDELSTAM, C., NORDLANDER, R., PEHRSSON, S. K., & RYDEN, L.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
1992-06
Volume
15
Issue
6
Pages
905-915
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2060082762
Cited by
39
References
0
FWCI
2.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Double‐Blind Study of Submaximal Exercise Tolerance and Variation in Paced Rate in Atrial Synchronous Compared to Activity Sensor Modulated Ventricular Pacing. https://app.cochat.ai/papers/10.1111/j.1540-8159.1992.tb03081.x
The paper
LINDE‐EDELSTAM, C., NORDLANDER, R., PEHRSSON, S. K., & RYDEN, L. (1992). A Double‐Blind Study of Submaximal Exercise Tolerance and Variation in Paced Rate in Atrial Synchronous Compared to Activity Sensor Modulated Ventricular Pacing. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1992.tb03081.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.