CoChat

Effects on Cardiac Performance of Atrioventricular Node Catheter Ablation Using Radiofrequency Current for Drug‐Refractory Atrial Arrhythmias

TWIDALE, NICHOLAS, SUTTON, KAYE, BARTLETT, LYN, DOOLEY, ALISON, WINSTANLEY, SUSAN, HEDDLE, WILLIAM, HASSAM, RHONDA, KOUTSOUNIS, HARI · 1993 · Pacing and Clinical Electrophysiology
Cited by 116

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Patients with atrial fibrillation or atrial flutter (AF) are candidates for radiofrequency (RF) catheter ablation of the atrioventricular (AV) node with the aim being to control heart rate. As patients wilh AF can have markedly impaired ventricular function, information concerning the hemodynamic effects of AV node ablation using RF current would be valuable. Fourteen consecutive patients (mean age 65 ± 3 years) with drug‐resistant AF underwent AV node catheter ablation with RF current and had permanent pacemaker implantation. The mean left ventricular ejection fraction (FFJ by two‐dimensional echoeardiography immediately before ablation was 42 ± 3% (range 14%–54%) and their mean exercise time was 4.4 ± 0.4 minutes. Complete AV block was achieved in all 14 patients with 6 ± 2 RF applications (range 1–18). There was no evidence of any acute cardiodepressant effect associated with delivery of RF current, and EF 3 days after ablation was 44 ± 4%. By 6 weeks after ablation, the left ventricular EF was significantly improved compared to baseline (47 ± 4% postablation vs 42 ± 3% preahlation; P < 0.05), and this modest increase in EF was accompanied by an improvement in exercise time (5.4 ± 0.4 min). In conclusion, delivery of RF current for AV node catheter ablation in patients with AF and reduced ventricular function is not associated with any acute cardiodepressant effect. On the contrary, improved control of rapid heart rate following successful AV node ablation is associated with a modest and progressive improvement in cardiac performance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.1993.tb01714.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 116

Metadata

Authors
TWIDALE, N., SUTTON, K., BARTLETT, L., DOOLEY, A., WINSTANLEY, S., HEDDLE, W., HASSAM, R., & KOUTSOUNIS, H.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
1993-06
Volume
16
Issue
6
Pages
1275-1284
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W1976458171
Cited by
116
References
1
FWCI
5.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects on Cardiac Performance of Atrioventricular Node Catheter Ablation Using Radiofrequency Current for Drug‐Refractory Atrial Arrhythmias. https://app.cochat.ai/papers/10.1111/j.1540-8159.1993.tb01714.x
The paper
TWIDALE, N., SUTTON, K., BARTLETT, L., DOOLEY, A., WINSTANLEY, S., HEDDLE, W., HASSAM, R., & KOUTSOUNIS, H. (1993). Effects on Cardiac Performance of Atrioventricular Node Catheter Ablation Using Radiofrequency Current for Drug‐Refractory Atrial Arrhythmias. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1993.tb01714.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.