CoChat

Magnetocardiographic Localization of the Origin of Ventricular Ectopic Beats

OEFF, MICHAEL, BURGHOFF, MARTIN · 1994 · Pacing and Clinical Electrophysiology
Cited by 21

The DOI matches its Crossref record.

Abstract

Magnetocardiogruphic mapping opens new perspectives for three‐dimensional localization of cardiac electrical activation. Using a 37‐channel SQUID magnetometer equipment with high shielding, the origin of abnormal ventricular aclivalion was investigated in 18 patients ivith Wolff‐Parkinson‐White syndrome prior to catheter ablation and in 5 of 31 patients with coronary artery disease having a sufficient number of monomorphic ventricular extrasystoies to enable evaluation. In ali WPW‐patients, the site of the earliest dello‐wave activation was projected onto the AV‐valve plane in accordance with the MR images. The result of magnetocardiographic localization was then compared to the site of successful catheter oblation delermined by digital imaging processing. After optimization of the algorithms, both sites were in the various planes at the foliowing distance from each other; X‐plane; 0.8 ± 0.9 cm, Y‐pIane; 1.1 ± 1.0 cm and Z‐piane; 1.5 ± 1.0 cm. In three‐dimensional projection, the mean difference in space between both positions was calculated to be 2.1 ± 1.7 cm. After this vahdofion ventricular premature beats were localized in another group of patients. In 4 of 5 palienfs their origin was found at the border of infarct areas. In each case, the progression of the ventricular activation couid be pursued. The detected structure of the magnetic field distribution of the VBP's exhibited a stable bipolar patlern, which is comparable to that of venlricuiar tachycardia, and its algorithms may be used to localize the origin of ventricular lachycardia. Thus, non‐invasive magnetocardiographic mapping localizes abnormal ventricuiar activations with fair accuracy, which makes it an useful adjunct for invasive investigations as well as studies of the pathophysiology of arrhythmias.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.1994.tb01420.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 21

Metadata

Authors
OEFF, M., & BURGHOFF, M.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
1994-03
Volume
17
Issue
3
Pages
517-522
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2090254868
Cited by
21
References
0
FWCI
0.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnetocardiographic Localization of the Origin of Ventricular Ectopic Beats. https://app.cochat.ai/papers/10.1111/j.1540-8159.1994.tb01420.x
The paper
OEFF, M., & BURGHOFF, M. (1994). Magnetocardiographic Localization of the Origin of Ventricular Ectopic Beats. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1994.tb01420.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.