CoChat

Quality‐of‐Life in DDDR Pacing: Atrioventricular Synchrony or Rate Adaptation?

LAU, CHU‐PAK, TAI, YAU‐TING, LEE, PETER W.H., CHEUNG, BEN, TANG, MAN‐OI, LAM, WAH‐KING · 1994 · Pacing and Clinical Electrophysiology
Cited by 34

The DOI matches its Crossref record.

Abstract

Al though differences in exercise performance have been observed between different rate adaptive modes, the relative impact of atrioventricular (AV) synchrony and rate adaptation on quality of life (QOL) have not been determined. Thirty‐three patients with either sinoatrial disease (18) or complete atrioventricular (AV) block (15) received DDDR pacemakers (16 minute ventilation sensing, 17 activity sensing). There were 11 males and 22 females, with a mean age of 66 ± 1 (range 39–78) years. The study was a double‐blind, triple cross‐over study comparing DDDR, DDD, and VVIR modes. At the end of each 8‐week study period in each mode, QOL was assessed by a questionnaire evaluating patients' functional class (Classes I‐IV), physical malaise inventory (41 items), illness perception (43 items), and overall QOL rating based on a 48 items measure covering different aspects of the patients' daily life adjustment. Two patients required early crossover from VVIR mode during the study. Patients experienced significantly fewer physi cal malaise such as temperature intolerance, dyspnea, and palpitations in the DDDR mode, compared with either DDD or VVIR pacing. DDDR pacing reduced the perception of illness in 5 of 43 items compared to VVIR pacing, and improved stamina and appetite compared to DDD pacing. The overall QOL score was 102 ± 2, 105 ± 2, 113 ± 2 in the DDDR, DDD, and VVIR modes, respectively, with a higher score indicating a poorer QOL (DDDR/DDD vs VVIR, P < 0.02). There was no change in functional classes between the three pacing modes. In conclusion, VVIR pacing has a lower QOL compared with DDD pacing, which can be further enhanced with rate augmentation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.1994.tb03759.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 11

  1. Lau CP., 1993, Rate Adaptive Cardiac Pacing: Single and Dual Chambers, NY, 337
  2. 10.1111/j.1540-8159.1990.tb06900.x · DOI
  3. 10.1016/0002-8703(91)90518-M · DOI
  4. Sutton R, 1990, DDDR pacing in severe chronotropic incompetence, RBM, 12, 56
  5. 10.1161/01.CIR.64.6.1227 · DOI · Paper page
  6. 10.1192/bjp.158.3.379 · DOI · Paper page
  7. Lau CP, 1994, The effects of radiofre qnency ablation on quality of life and exercise capacity in patients with accessory pathway me diated tachycardia: A treatment comparison study, PACE
  8. 10.1002/clc.4960120907 · DOI
  9. 10.1111/j.1540-8159.1991.tb04110.x · DOI
  10. 10.1136/hrt.65.4.188 · DOI
  11. Lau CP, 1994, Rate adaptive pacing in sick sinns syndrome: Effects of pacing modes and intrinsic conduction on physiological responses, arrhythmias, symptomatology and quality of life, Eur Heart J

Cited by

See all 34

Metadata

Authors
LAU, C., TAI, Y., LEE, P. W. H., CHEUNG, B., TANG, M., & LAM, W.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
1994-11
Volume
17
Issue
11
Pages
1838-1843
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W1970261629
Cited by
34
References
0
FWCI
1.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quality‐of‐Life in DDDR Pacing: Atrioventricular Synchrony or Rate Adaptation? https://app.cochat.ai/papers/10.1111/j.1540-8159.1994.tb03759.x
The paper
LAU, C., TAI, Y., LEE, P. W. H., CHEUNG, B., TANG, M., & LAM, W. (1994). Quality‐of‐Life in DDDR Pacing: Atrioventricular Synchrony or Rate Adaptation? Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1994.tb03759.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.