CoChat

Long‐Term Clinical Outcome of Right Bundle Branch Radiofrequency Catheter Ablation for Treatment of Bundle Branch Reentrant Ventricular Tachycardia

MEHDIRAD, ALI AKBAR, KEIM, STEPHEN, RIST, KEVIN, TCHOU, PATRICK · 1995 · Pacing and Clinical Electrophysiology
Cited by 75

The DOI matches its Crossref record.

Abstract

This study assessed the long‐term outcome of patients undergoing radiofrequency ablation of the right bundle for bundle branch reentrant ventricular tachycardia. Bundle branch reentrant tachycardia was diagnosed in 16 patients (ejection fraction 31%± 15%) who underwent electrophysiology study in our laboratory. All patients had His‐Purkinje system conduction delay with mean HV interval of 68 ± 8 ms. After ablation, right bundle branch block developed in 15 patients. One patient developed complete heart block, which was anticipated. One patient died of heart failure 9 months after ablation. Two patients were successfully bridged to heart transplantation 0.5 and 13 months, respectively, after ablation. Two patients received implantable defibrillators for other ventricular tachycardias. One patient had syncope 11 months after ablation, but there was no evidence of ventricular tachycardia or heart block in repeat electrophysiology study. This patient died suddenly 29 months after ablation. The remaining nine patients were alive and well for a mean follow‐up of 19 ± 10 months. Radiofrequency ablation of the right bundle branch is an effective therapy for treatment of bundle branch reentrant ventricular tachycardia. Survival is excellent provided that other types of ventricular tachycardia, when present, are treated as well. This technique maybe helpful in management of patients who have unacceptable frequent shocks from their implanted defibrillators and may be helpful in avoiding implantation of such a device completely in others. In some patients with terminal heart failure and incessant ventricular tachycardia, this procedure can function as a bridge to cardiac transplantation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.1995.tb04638.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 75

Metadata

Authors
MEHDIRAD, A. A., KEIM, S., RIST, K., & TCHOU, P.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
1995-12
Volume
18
Issue
12
Pages
2135-2143
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2001688531
Cited by
75
References
0
FWCI
1.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Long‐Term Clinical Outcome of Right Bundle Branch Radiofrequency Catheter Ablation for Treatment of Bundle Branch Reentrant Ventricular Tachycardia. https://app.cochat.ai/papers/10.1111/j.1540-8159.1995.tb04638.x
The paper
MEHDIRAD, A. A., KEIM, S., RIST, K., & TCHOU, P. (1995). Long‐Term Clinical Outcome of Right Bundle Branch Radiofrequency Catheter Ablation for Treatment of Bundle Branch Reentrant Ventricular Tachycardia. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1995.tb04638.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.