ECG Criteria to Distinguish Between Aberrantly Conducted Supraventricular Tachycardia and Ventricular Tachycardia:Practical Aspects for the Immediate Care Setting
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
To reevaluate ECG criteria for distinguishing Supraventricular tachycardia (SVT) with aberrant conduction from ventricular tachycardia (VT), 133 wide QRS tachycardias were recorded in patients undergoing invasive electrophysiological (EP) study. Surface ECG leads (standard 12‐lead and MCL leads) were compared to EP recordings to provide a standard for correct diagnosis. Criteria from six studies were pooled to select QRS morphology agreed to be highly specific for SVT or VT (specificity > 90%). Some morphological criteria were modified to simplify analysis for the immediate care setting. Results: Although the 12‐lead ECG was useful in distinguishing aberrancy from VT, 13 tachycardias (10%) were misdiagnosed or could not be diagnosed. The MCL 1 lead recorded clearly different QRS morphology than lead V 1 in 40% of VT cases and was diagnostically inferior to V 1.Most established criteria were highly specific for a diagnosis, but not very sensitive as individual criteria. Neither a QRS width of > 0.14 seconds nor a monophasic R wave pattern in lead V 1 were valuable in diagnosing VT. Conclusions: In distinguishing SVT with aberrant conduction from VT: (1) Although the 12‐lead ECG is valuable, about 1 in 10 wide QRS tachycardias defy differentiation; (2) tachycardias > 190 beats/mm often do not exhibit unequivocal criteria with which to make a certain diagnosis; (3) multiple leads are required for accurate assessment of QRS width, presence of AV dissociation or VA block, QRS axis, and morphological criteria; and (4) the MCL 1 lead cannot be substituted for V 1 in the use of morphological criteria for VT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new approach to the differential diagnosis of a regular tachycardia with a wide QRS complex
Brugada, P., Brugada, J., Mont, L., Smeets, J., & Andries, E. W. (1991) · Circulation · doi:10.1161/01.cir.83.5.1649 · Cited by 738
Wellens, H. J. J., Bär, F. W. H. M., & Lie, K. I. (1978) · The American Journal of Medicine · doi:10.1016/0002-9343(78)90176-6 · Cited by 538
Kindwall, K. E., Brown, J., & Josephson, M. E. (1988) · The American Journal of Cardiology · doi:10.1016/0002-9149(88)91169-1 · Cited by 253
Enhanced atrioventricular conduction during atrial flutter after intravenous adenosine
Brodsky, M. A., Allen, B. J., Grimes, J. A., & Gold, C. (1994) · New England Journal of Medicine · doi:10.1056/nejm199401273300413 · Cited by 15
Cited by
Drew, B. J., Califf, R. M., Funk, M., Kaufman, E. S., Krucoff, M. W., Laks, M. M., Macfarlane, P. W., Sommargren, C., Swiryn, S., & Van Hare, G. F. (2004) · Circulation · doi:10.1161/01.cir.0000145144.56673.59 · Cited by 609
Self-citationNew algorithm using only lead aVR for differential diagnosis of wide QRS complex tachycardia
Vereckei, A., Duray, G., Szénási, G., Altemose, G. T., & Miller, J. M. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2007.09.020 · Cited by 280
Application of a new algorithm in the differential diagnosis of wide QRS complex tachycardia
Vereckei, A., Duray, G., Szenasi, G., Altemose, G. T., & Miller, J. M. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl473 · Cited by 247
“Using all these traditional ECG criteria, an accurate diagnosis is now possible in about 90% of WCTs. 2,3,10 However, many of these criteria are complicated and not consistently present, thus not useful in an urgent setting.”
MethodInfluentialGarner, J. B., Miller, J. M., Fellow, C. E., & Professor of Medicine and Director, C. C. E. A. T. P. (2013) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2013.2.1.23 · Cited by 38
Metadata
- Authors
- DREW, B. J., & SCHEINMAN, M. M.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1995-12
- Volume
- 18
- Issue
- 12
- Pages
- 2194-2208
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2083445503
- Cited by
- 71
- References
- 4
- FWCI
- 1.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.