The DOI matches its Crossref record; 35 of the 37 references it cites were found in a registry or an index.
Atrial Flutter Mapping and Ablation I: Studying Atrial Flutter Mechanisms by Mapping and Entrainment
Abstract
Endocardial mapping has led to a detailed knowledge of reentry mechanisms in atrial flutter. Multipolar and deflecting tip catheters allow recording local electrograms from multiple areas of the right atrium, and from the coronary sinus. In common flutter, with the typical "sawtooth" pattern, there is circular activation of the right atrium in a "counterclockwise" direction, descending in the anterior and lateral walls, and ascending in the septum and posterior wall. Superior and inferior vena cava, linked by a "line" of functional block in the posterolateral wall, make the central obstacle for circular activation. The cranial and caudal turning points are the atrial "roof," and the isthmus between the inferior vena cava and the tricuspid valve. Complex conduction patterns, probably including slow conduction are detectable in the low septal area, around the coronary sinus. Atypical flutter, without the sharp negative deflections of common flutter, sometimes shows circular activation in the right atrium, rotating in the opposite direction of common flutter (clockwise). Other atypical flutters show no circular right atrial activation, and only partial data from coronary sinus activation, combined with the response to atrial stimulation (entrainment) allow the diagnosis of left atrial reentry, without a precise delimitation of the circuits. In patients having undergone cardiac surgery, atypical flutter may be based on reentry around surgical scars. To our knowledge, the mechanism of type II flutter has not been disclosed in humans.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Atrial mapping studies have identified the mechanism of typical AFL as a macroreentrant circuit contained in the right atrium (RA) with passive activation of the left atrium (Figure 11).122”
From European Heart Rhythm Association (EHRA) consensus document on the management of supraventricular arrhythmias, endorsed by Heart Rhythm Society (HRS), Asia-Pacific Heart Rhythm Society (APHRS), and Sociedad Latinoamericana de Estimulacion Cardiaca y Electrofisiologia (SOLAECE) (2017) · cites this paper as [122]
Citations
Cites
Spach, M. S., Miller, W. T., Dolber, P. C., Kootsey, J. M., Sommer, J. R., & Mosher, C. E. (1982) · Circulation Research · doi:10.1161/01.res.50.2.175 · Cited by 535
Feld, G. K., FLECK, R. P., Chen, P., Boyce, K., Bahnson, T. D., Stein, J. B., Calisi, C. M., & Ibarra, M. (1992) · Circulation · doi:10.1161/01.cir.86.4.1233 · Cited by 526
Olgin, J. E., Kalman, J. M., Fitzpatrick, A. P., & Lesh, M. D. (1995) · Circulation · doi:10.1161/01.cir.92.7.1839 · Cited by 500
Radiofrequency catheter ablation of atrial arrhythmias. Results and mechanisms.
Lesh, M. D., Hare, G. F. V., Epstein, L. M., Fitzpatrick, A. P., Scheinman, M. M., Lee, R. J., Kwasman, M. A., Grogin, H. R., & Griffin, J. C. (1994) · Circulation · doi:10.1161/01.cir.89.3.1074 · Cited by 455
Waldo, A. L., MacLean, W. A. H., Karp, R. B., Kouchoukos, N. T., & James, T. N. (1977) · Circulation · doi:10.1161/01.cir.56.5.737 · Cited by 443
Saffitz, J. E., Kanter, H. L., Green, K. G., Tolley, T., & Beyer, E. C. (1994) · Circulation Research · doi:10.1161/01.res.74.6.1065 · Cited by 297
Allessie, M. A., Lammers, W. J. E. P., Bonke, I. M., & Hollen, J. (1984) · Circulation · doi:10.1161/01.cir.70.1.123 · Cited by 275
Wells, J. L., MacLean, W. A. H., James, T. N., & Waldo, A. L. (1979) · Circulation · doi:10.1161/01.cir.60.3.665 · Cited by 257
Demonstration of an area of slow conduction in atrial flutter
Olshansky, B., Okumura, K., Hess, P. G., & Waldo, A. L. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90314-f · Cited by 241
Fitzpatrick, A. P., Gonzales, R. P., Lesh, M. D., odin, G. W., Lee, R. J., & Scheinman, M. M. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90508-8 · Cited by 232
Triedman, J. K., Saul, J. P., Weindling, S. N., & Walsh, E. P. (1995) · Circulation · doi:10.1161/01.cir.91.3.707 · Cited by 217
Catheter ablation of the atrial myocardium in human type I atrial flutter.
Saoudi, N. C., Atallah, G., Kirkorian, G., & Touboul, P. (1990) · Circulation · doi:10.1161/01.cir.81.3.762 · Cited by 184
Radiofrequency catheter ablation of common atrial flutter in 80 patients
Fischer, B., Haı̈ssaguerre, M., Garrigues, S., POQUET, F., Gencel, L., Clémenty, J., & Marcus, G. M. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00029-4 · Cited by 182
Okumura, K., Henthorn, R. W., Epstein, A. E., Plumb, V. J., & Waldo, A. L. (1985) · Circulation · doi:10.1161/01.cir.72.6.1293 · Cited by 169
Validation of double-spike electrograms as markers of conduction delay or block in atrial flutter
Cosío, F. G., Arribas, F., Barbero, J. M., Kallmeyer, C., & Goicolea, A. (1988) · The American Journal of Cardiology · doi:10.1016/0002-9149(88)91065-x · Cited by 155
Self-citation(2013) · Heart Disease · doi:10.5040/9798400662577.ch-006 · Cited by 152
Characterization of double potentials in human atrial flutter: Studies during transient entrainment
Olshansky, B., Okumura, K., Henthorn, R. W., & Waldo, A. L. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90283-u · Cited by 146
A fourth criterion for transient entrainment: the electrogram equivalent of progressive fusion.
Henthorn, R. W., Okumura, K., Olshansky, B., Plumb, V. J., Hess, P. G., & Waldo, A. L. (1988) · Circulation · doi:10.1161/01.cir.77.5.1003 · Cited by 140
Fragmented electrograms and continuous electrical activity in atrial flutter
Cosío, F. G., Arribas, F., Palacios, J., Tascon, J. C., & López‐Gil, M. (1986) · The American Journal of Cardiology · doi:10.1016/0002-9149(86)90210-9 · Cited by 116
Self-citationSIMINIAK, T., Flores, N. A., & Sheridan, D. J. (1995) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a060880 · Cited by 111
The Disorders of Cardiac Rhythm
Greenberg, H. B. (1972) · JAMA · doi:10.1001/jama.1972.03190390052032 · Cited by 107
The Atrium in health and disease
ATTUEL, P., Coumel, P., & Janse, M. J. (1989) · Futura Pub. Co. eBooks · Cited by 96
Atrial endocardial mapping in the rare form of atrial flutter
Cosío, F. G., Goicolea, A., López‐Gil, M., Arribas, F., Barroso, J., & Chicote, R. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)91136-t · Cited by 93
Self-citationRacker, D. K. (1989) · The Anatomical Record · doi:10.1002/ar.1092240303 · Cited by 90
Mechanisms of entrainment of human common flutter studied with multiple endocardial recordings.
Cosío, F. G., Gil, M. L., Arribas, F., Palacios, J., Goicolea, A., & Núñez, A. (1994) · Circulation · doi:10.1161/01.cir.89.5.2117 · Cited by 88
Self-citationWatanabe, H., Kakihana, M., Ohtsuka, S., Enomoto, T., Yasui, K., & Sugishita, Y. (1993) · Circulation · doi:10.1161/01.cir.88.1.29 · Cited by 65
Bruyne, B. D., Bronzwaer, J. G. F., Heyndrickx, G. R., & Paulus, W. J. (1993) · Circulation · doi:10.1161/01.cir.88.2.461 · Cited by 54
Catheter Ablation of Atrial Flutter Circuits
Cosío, F. G., Goicolea, A., López‐Gil, M., & Arribas, F. (1993) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1993.tb01636.x · Cited by 49
Self-citationRacker, D. K., Ursell, P. C., & Hoffman, B. F. (1991) · Circulation · doi:10.1161/01.cir.84.2.841 · Cited by 48
Classic and Concealed Entrainment of Typical and Atypical Atrial Flutter
Beckman, K. J., HUANG‐TA‐LIN, Krafchek, J., & Wyndham, C. R. C. (1986) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1986.tb06632.x · Cited by 38
Arenal, Á., Almendral, J. M., Román, D. S., Delcán, J. L., & Josephson, M. E. (1992) · The American Journal of Cardiology · doi:10.1016/0002-9149(92)90764-p · Cited by 36
The Role of Catheter Ablation Techniques in the Treatment of Classic (Type 1) Atrial Flutter
Saoudi, N. C., Dérumeaux, G., Cribier, A. G., & Letac, B. (1991) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1991.tb02809.x · Cited by 32
Cronin, C. S., Nitta, T., Mitsuno, M., Isobe, F., Schuessler, R. B., Boineau, J. P., & Cox, J. L. (1993) · PubMed · Cited by 32
Interventional electrophysiology : a textbook
Saksena, S. V., & Lüderitz, B. (1996) · Futura eBooks · Cited by 30
Geometrically accurate activation mapping of the atrioventricular node region during surgery
Saumarez, R. C., Parker, J. O., & Camm, A. J. (1992) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(10)80279-7 · Cited by 21
Research works printed but not linked: 8
- Puech P, 1956, L'ActivitéÉlectrique Auriculaire Normale et Pathologique
- Puech P, 1970, Le flutter et ses limites, Arch Mal Coeur, 63, 116
- Chauvin M, 1983, Application de la cartographic endocavitaire a l'etude du flutter auriculaire, Arch Mal Coeur, 76, 1020
- Cosio FG, 1993, Cardiac Mapping, 443
- Nunez A, 1995, A study of the mechanism of atrial flutter and atrial tachycardia in adults by mapping and pacing, PACE, 18, 803
- Arribas F, 1994, The upper link of the common atrial flutter circuit, Circulation, 90, 376
- Lopez Gil M, 1993, Different local conduction in right atrial flutter circuits with clockwise and counterclockwise rotation, Circulation, 88, 29
- López‐Gil M, 1995, Mapping and ablation of right atrial free wall re‐entry circuits after open‐heart surgery: “Flutter around a scar.”, Eur Heart J, 16, 160
Cited by
Sorted by citations
Saoudi, N., Cosío, F., Waldo, A., Chen, S. A., Iesaka, Y., Lesh, M., Saksena, S., Salerno, J., & Schoels, W. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2658 · Cited by 464
A Computer Model of Normal Conduction in the Human Atria
Harrild, C. S. H. D. M. (2000) · Circulation Research · doi:10.1161/01.res.87.7.e25 · Cited by 278
Holm, M. (1998) · Cardiovascular Research · doi:10.1016/s0008-6363(97)00289-7 · Cited by 275
Three-dimensional Mapping of the Common Atrial Flutter Circuit in the Right Atrium
Shah, D. C., Jaı̈s, P., Haı̈ssaguerre, M., Chouairi, S., Takahashi, A., Hocini, M., Garrigue, S., & Clémenty, J. (1997) · Circulation · doi:10.1161/01.cir.96.11.3904 · Cited by 205
Katritsis, D. G., Boriani, G., Cosio, F. G., Hindricks, G., Jaïs, P., Josephson, M. E., Keegan, R., Kim, Y.-H., Knight, B. P., Kuck, K.-H., et al. (2017) · Europace · doi:10.1093/europace/euw301 · Cited by 188
Metadata
- Authors
- COSIO, F. G., ARRIBAS, F., LÓPEZ‐GIL, M., & PALACIOS, J.
- Affiliations
- Hospital Universitario 12 De Octubre (ES)
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1996-05
- Volume
- 19
- Issue
- 5
- Pages
- 841-853
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W1573969966
- Cited by
- 111
- References
- 37
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 3 · 2022: 1 · 2021: 2 · 2020: 3 · 2019: 1 · 2017: 1 · 2016: 1 · 2015: 2 · 2014: 1 · 2013: 1 · 2012: 6
- FWCI
- 2.80
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Pacing and Clinical Electrophysiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Keywords
- atrial flutter, endocardial mapping, catheter ablation, reentry mechanism, coronary sinus electrogram, inferior vena cava, atrial stimulation
- MeSH terms
- Atrial Flutter, Cicatrix, Coronary Vessels, Electrocardiography, Heart Atria, Heart Septum, Cardiac Surgical Procedures, Humans, Cardiomyopathies, Neural Conduction, Tricuspid Valve, Vena Cava, Inferior, Vena Cava, Superior, Catheter Ablation, Body Surface Potential Mapping
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review