CoChat

Atrioventricular Node Reentry: Physiology and Radiofrequency Ablation

PRYSTOWSKY, ERIC N. · 1997 · Pacing and Clinical Electrophysiology
Cited by 56

The DOI matches its Crossref record.

Abstract

Atrioventricular (A V) node reentry has heen recognized as a clinical arrhythmia for many years. Earlier basic investigations identified a dual AV conduction system, and atrial echo beats occurred when the refractory period of the slow conduction pathway was shorter than the fast pathway. Subsequent studies in humans confirmed the concept of dual AV node physiology and AV node reentry. Slow‐fast AV node reentry (anterograde conduction over the slow pathway and retrograde conduction over the fast pathway) occurs most frequently. The fast‐slow and intermediate varieties are much less common. A high (> 95%) cure rate occurs with radiofrequency catheter ablation with experienced electrophysiologists. Most electrophysiologists prefer the posterior approach, which results in absence or very poor conduction over the slow AV node pathway; the PR interval is minimally changed. This approach is highly successful for all three forms of AV node reentry and associated with a 1%–2% incidence of heart block in most experienced laboratories.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.1997.tb06210.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 56

Metadata

Authors
PRYSTOWSKY, E. N.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
1997-02
Volume
20
Issue
2
Pages
552-571
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2161689574
Cited by
56
References
0
FWCI
2.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Atrioventricular Node Reentry: Physiology and Radiofrequency Ablation. https://app.cochat.ai/papers/10.1111/j.1540-8159.1997.tb06210.x
The paper
PRYSTOWSKY, E. N. (1997). Atrioventricular Node Reentry: Physiology and Radiofrequency Ablation. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1997.tb06210.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.