Electroanatomical Mapping of the Heart: Basic Concepts and Implications for the Treatment of Cardiac Arrhythmias
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The CARTO electroanatomical mapping system represents a paradigm shift in the ability to map the three‐dimensional anatomy of the heart and determine the cardiac electrical activity at any given mapped point. The system associates anatomical structure and electrophysiological data and displays the combined information in an easily readable, visual fashion. The system consists of a roving mapping catheter with small magnetic sensors in the tip, a fixed sensor that acts as a reference point, a low magnetic field generating pad, and a data acquisition and display system. When the roving catheter is moved in three‐dimensional space, its location in relation to the fixed sensor is monitored by the system, with a resolution of < 1 mm. By gating the acquisition of points in space to the cardiac electrical activity, points that represent both location and electrical activity at that location can be acquired and displayed on a computer screen. After acquiring a number of points, a three‐dimensional representation is constructed, and may be displayed from any viewing projection. Clinical applications of the system include defining the mechanisms of arrhythmias, designing ablation strategies, guiding ablations, and improving the safety of mapping and ablation procedures by allowing localization of critical cardiac structures such as the atrioventricular node and His bundle. The system holds the potential to both further our understanding of arrhythmias and increase the safety, efficacy, and efficiency of catheter ablation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jackman, W. M., Wang, X., Friday, K. J., Roman, C. A., Moulton, K. P., Beckman, K. J., McClelland, J. H., Twidale, N., Hazlitt, H. A., Prior, M. I., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199106063242301 · Cited by 1,422
Cited by
de Groot, N. M. S., Atary, J. Z., Blom, N. A., & Schalij, M. J. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.909838 · Cited by 108
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
de Groot, N. M. S., Lukac, P., Schalij, M. J., Makowski, K., Szili-Torok, T., Jordaens, L., Nielsen, J. C., Jensen, H. K., Gerdes, J. C., & Delacretaz, E. (2012) · Europace · doi:10.1093/europace/eur313 · Cited by 54
Metadata
- Authors
- GEPSTEIN, L., & EVANS, S. J.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1998-06
- Volume
- 21
- Issue
- 6
- Pages
- 1268-1278
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W1993114949
- Cited by
- 112
- References
- 1
- FWCI
- 5.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electroanatomical Mapping of the Heart: Basic Concepts and Implications for the Treatment of Cardiac Arrhythmias. https://app.cochat.ai/papers/10.1111/j.1540-8159.1998.tb00187.x
- The paper
- GEPSTEIN, L., & EVANS, S. J. (1998). Electroanatomical Mapping of the Heart: Basic Concepts and Implications for the Treatment of Cardiac Arrhythmias. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1998.tb00187.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.