The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Prevalence of supraventricular arrhythmias from the automated analysis of data stored in the DDD pacemakers of 617 patients: the AIDA study
Abstract
The confirmation of the occurrence of supraventricular arrhythmias (SVAs) is possible only if a surface electrocardiogram (ECG) is recorded during an episode, or if SVAs occur during 24 h ambulatory monitoring (Holter). The automatic interpretation of memory functions in DDD pacemakers may be useful in this diagnostic task over longer periods of follow up. This hypothesis was tested in 384 men and 233 women (mean age = 70 ± 11 years) who had received Chorus 6034/6035, 6234 or 7034 pacemakers (ELA Medical, Montrouge, France) with fall‐back function in case of sustained SVAs. The Automatic Interpretation for Diagnostic Assistance (AIDA) algorithm included in these pacemakers was compared with 24 h Holters recorded simultaneously (DI) and with the clinical history of symptoms consistent with SVAs up to 28 days of follow up (D28). Indications for pacing were atrioventricular block (AVB) in 269 patients, sinus node dysfunction (SND) in 248, and AVB + SND in 100. SVAs were documented before implant in 199 patients (32%). Among the 617 patients included at D1. 76 (12.4%) developed at least one SVA episode, lasting between 1 min and 24 hours, simultaneously recorded on Holter and by AIDA with a 93.8% sensitivity and 94.2% specificity. Data from 354 patients were available for analysis at D28. AIDA diagnosed SVAs in 179 patients (50.6%), 104 of whom (65%) had remained asymptomatic and 117 of whom (65%) had had no SVA documented before implant. Among the 354 patients, AIDA diagnosed SVAs in 76 (21%) asymptomatic patients who had no known SVA before implant. The prevalence of SVA in our AVB population was higher than reported in previous studies: 89 patients (56.3%) with AVB had SVAs versus 90 patients (45.9%) with other diagnoses (p=0.55). Furthermore atrial pacing was associated with fewer SVAs. These first clinical results of the AIDA study demonstrate that the memory functions of Chorus pacemakers and the AIDA software are reliable to analyze the prevalence of SVA at 1 month of follow‐up. From a clinical point of view, AIDA is a valuable tool to evaluate the efficacy of antiarrhythmic therapy, particularly as it pertains to the prevention of stroke due to atrial fibrillation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Benjamin, E. J. (1994) · JAMA · doi:10.1001/jama.1994.03510350050036 · Cited by 2,613
Cited by
Glotzer, T. V., Hellkamp, A. S., Zimmerman, J., Sweeney, M. O., Yee, R., Marinchak, R., Cook, J., Paraschos, A., Love, J., Radoslovich, G., et al. (2003) · Circulation · doi:10.1161/01.cir.0000057981.70380.45 · Cited by 750
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 556
Long-term risk of recurrent atrial fibrillation as documented by an implantable monitoring device
Israel, C. W., Grönefeld, G., Ehrlich, J. R., Li, Y.-G., & Hohnloser, S. H. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.08.027 · Cited by 480
Savelieva, I., & Camm, A. J. (2000) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/a:1009823001707 · Cited by 339
Automatic Real Time Detection of Atrial Fibrillation
Dash, S., Chon, K. H., Lu, S., & Raeder, E. A. (2009) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9740-z · Cited by 313
Metadata
- Authors
- DEFAYE, P., DOURNAUX, F., MOUTON, E., & for the AIDA MULTICHNTER STUDY GROUP.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1998-01
- Volume
- 21
- Issue
- 1
- Pages
- 250-255
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2049893530
- Cited by
- 182
- References
- 1
- FWCI
- 4.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prevalence of supraventricular arrhythmias from the automated analysis of data stored in the DDD pacemakers of 617 patients: the AIDA study. https://app.cochat.ai/papers/10.1111/j.1540-8159.1998.tb01098.x
- The paper
- DEFAYE, P., DOURNAUX, F., MOUTON, E., & for the AIDA MULTICHNTER STUDY GROUP. (1998). Prevalence of supraventricular arrhythmias from the automated analysis of data stored in the DDD pacemakers of 617 patients: the AIDA study. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1998.tb01098.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.