CoChat

Conversion of Recent‐Onset Atrial Fibrillation to Sinus Rhythm: Effects of Different Drug Protocols

Open access
BORIANI, GIUSEPPE, BIFFT, MAURO, CAPUCCI, ALESSANDRO, BOTTO, GIANLUCA, BROFFONI, TIZIANA, ONGARI, MAURIZIO, TRISOLINO, GIUSEPPE, RUBINO, IDA, SANGUINETTI, MARIO, BRANZI, ANGELO, MAGNANI, BRUNO · 1998 · Pacing and Clinical Electrophysiology
Cited by 104

The DOI matches its Crossref record.

Abstract

In a population of 417 hospitalized patients, the efficacy and safety of different drug regimens administered to convert atrial fibrillation (AF) of recent anset (≤ 7 days duration) to sinus rhythm were evaluated. All patients were in NYHA Class ≤ 2, and free of heart failure. They were randomly allocated to treatment with placebo in 121 patients; IV amiodarone, 5 mg/kg bolus, followed by 1.8 g/24 hours in 51 patients; IV propafenone, 2 mg/kg bolus, followed by 0.0078 mg/kg/min in 57 patients; p.o. propafenone, 600 mg p.o. in a single dose in 119 patients; and p.o. flecainide, 300 mg p.o. in a single dose in 69 patients. All patients were continuously monitored by Holter ECG, and the number of conversions to sinus rhythm was measured at 1, 3, and 8 hours. Results: (1) IV propafenone resulted in a higher conversion rate within 1 hour compared with the oral loading regimens of propafenone or flecainide, but the conversion rates at 3 and 8 hours were comparable, approximately 75% at 8 hours; 2) IV amiodarone was not different from placebo until 8 hours when it was associated with 57% of conversions; (3) conversion to sinus rhythm at 8 hours was observed in 37% of the placebo treated patients. Serious adverse effects occurred in few patients: two patients treated with flecainide and one treated with IV propafenone experienced left ventricular decompensation; one patient treated with placebo and two treated with flecainide had atrial flutter with rapid ventricular response. In conclusion, single‐dose, oral loading with propafenone or flecainide are acceptable alternatives to conventional drug regimens in selected hospitalized patients. In addition, the measure of a placebo effect is mandatory in studies of recent‐onset AF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.1998.tb01203.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 104

Metadata

Authors
BORIANI, G., BIFFT, M., CAPUCCI, A., BOTTO, G., BROFFONI, T., ONGARI, M., TRISOLINO, G., RUBINO, I., SANGUINETTI, M., BRANZI, A., & MAGNANI, B.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
1998-11
Volume
21
Issue
11
Pages
2470-2474
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2145021382
Cited by
104
References
0
FWCI
4.95
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Conversion of Recent‐Onset Atrial Fibrillation to Sinus Rhythm: Effects of Different Drug Protocols. https://app.cochat.ai/papers/10.1111/j.1540-8159.1998.tb01203.x
The paper
BORIANI, G., BIFFT, M., CAPUCCI, A., BOTTO, G., BROFFONI, T., ONGARI, M., TRISOLINO, G., RUBINO, I., SANGUINETTI, M., BRANZI, A., & MAGNANI, B. (1998). Conversion of Recent‐Onset Atrial Fibrillation to Sinus Rhythm: Effects of Different Drug Protocols. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1998.tb01203.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.