CoChat

Intravenous Propafenone Versus Intravenous Amiodarone in the Management of Atrial Fibrillation of Recent Onset: A Placebo‐Controlled Study

KOCHIADAKIS, GEORGE E., IGOUMENIDIS, NIKOS E., SIMANTIRAKIS, EMMANUEL N., MARKETOU, MARIA E., PARTHENAKIS, FRAGISKOS I., MEZILIS, NIKOS E., VARDAS, PANOS E. · 1998 · Pacing and Clinical Electrophysiology
Cited by 51

The DOI matches its Crossref record.

Abstract

The efficacy and safety of intravenous propafenone, amiodarone, or placebo were compared in the treatment of atrial fibrillation (AF) of recent onset (duration ≤ 48 hours). Methods: 143 patients (77 men, mean age 63 ± 12 years) were studied, of whom 46 received propafenone (2 mg/kg over 15 minutes followed by 10 mg/kg over the next 24 hours), 48 received amiodarone (300 mg intravenously over 1 hour, followed by 20 mg/kg over the next 24 hours, plus 1,800 mg/day orally, in 3 divided doses), and 49 received placebo (the equivalent amount of saline IV over 24 hours). Digoxin was administered to all patients who had not previously received it. Results: Conversion to normal sinus rhythm occurred in 36 of 46 patients (78.2%) receiving propafenone, in 40 of 48 patients (83.3%) receiving amiodarone, and in 27 of the 49 (55.10%) controls (P < 0.02, drug vs placebo, between drugs NS). The mean time to conversion was 2 ± 3 hours for propafenone, 7 ± 5 hours for amiodarone, and 13 ± 9 for placebo (P < 0.05). Patients who converted had smaller atria than those who did not (diameter: 42.7 ± 5 vs 47.2 ± 7 mm, P < 0.001 for all). Treatment was discontinued in one patient in the amiodarone group because of an allergic reaction and in two patients in the propafenone group because of excessive QRS widening. No side effects were observed in the placebo group. Conclusions: Both drugs tested intravenously were equally effective and safe for the rapid conversion of recent‐onset atrial fibrillation to sinus rhythm. However, propafenone offered the advantage of more rapid conversion than amiodarone.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.1998.tb01204.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 51

Metadata

Authors
KOCHIADAKIS, G. E., IGOUMENIDIS, N. E., SIMANTIRAKIS, E. N., MARKETOU, M. E., PARTHENAKIS, F. I., MEZILIS, N. E., & VARDAS, P. E.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
1998-11
Volume
21
Issue
11
Pages
2475-2479
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W1964087992
Cited by
51
References
0
FWCI
2.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intravenous Propafenone Versus Intravenous Amiodarone in the Management of Atrial Fibrillation of Recent Onset: A Placebo‐Controlled Study. https://app.cochat.ai/papers/10.1111/j.1540-8159.1998.tb01204.x
The paper
KOCHIADAKIS, G. E., IGOUMENIDIS, N. E., SIMANTIRAKIS, E. N., MARKETOU, M. E., PARTHENAKIS, F. I., MEZILIS, N. E., & VARDAS, P. E. (1998). Intravenous Propafenone Versus Intravenous Amiodarone in the Management of Atrial Fibrillation of Recent Onset: A Placebo‐Controlled Study. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1998.tb01204.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.