CoChat

AV Node Ablation and Pacemaker Implantation After Withdrawal of Effective Rate‐Control Medications for Chronic Atrial Fibrillation: Effect on Quality of Life and Exercise Performance

NATALE, ANDREA, ZIMERMAN, LEANDRO, TOMASSONI, GERY, NEWBY, KEITH, LEONELLI, FABIO, FANELLI, RAFFAELE, BEHEIRY, SALWA, PISANO, ENNIO · 1999 · Pacing and Clinical Electrophysiology
Cited by 70

The DOI matches its Crossref record.

Abstract

We assess whether AV node ablation and pacemaker implantation after discontinuation of effective rate‐control medical therapy for chronic atrial fibrillation had a positive impact on quality of life and exercise performance. To assess the possibility of a placebo effect following pacemaker implantation, the study included three groups of patients. Group 1 underwent an echocardiogram, treadmill exercise, and quality of life measurement 1 month prior to and 6 months following AV node ablation and pacemaker implantation associated with discontinuation of rate‐control medications. Group 2 underwent AV node ablation and pacemaker implantation without discontinuation of antiarrhythmic rate‐control drugs. Group 3 underwent pacemaker implantation without performing AV node ablation and continuing rate‐control medical therapy. At the 1‐ and 6‐month evaluation, the patients in group 1 showed a significant improvement of left ventricular ejection fraction, quality of life, and activity scores. The exercise duration and the maximal VO 2 consumption, however, did not change significantly. A slight improvement of the quality of life and physical activity scores was observed in the group undergoing AV node ablation without withdrawal of medications. However, no significant changes were observed in the group receiving only the pacemaker without modification of medical therapy and with intact AV node conduction. In conclusion, in patients with chronic atrial fibrillation, discontinuation of effective rate‐control medical therapy followed by AV node ablation and permanent pacing appeared to improve quality of life and activity scores despite no change in exercise duration. The improvement observed does not seem to reflect a placebo effect.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.1999.tb00383.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 70

Metadata

Authors
NATALE, A., ZIMERMAN, L., TOMASSONI, G., NEWBY, K., LEONELLI, F., FANELLI, R., BEHEIRY, S., & PISANO, E.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
1999-11
Volume
22
Issue
11
Pages
1634-1639
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2137441418
Cited by
70
References
0
FWCI
3.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: AV Node Ablation and Pacemaker Implantation After Withdrawal of Effective Rate‐Control Medications for Chronic Atrial Fibrillation: Effect on Quality of Life and Exercise Performance. https://app.cochat.ai/papers/10.1111/j.1540-8159.1999.tb00383.x
The paper
NATALE, A., ZIMERMAN, L., TOMASSONI, G., NEWBY, K., LEONELLI, F., FANELLI, R., BEHEIRY, S., & PISANO, E. (1999). AV Node Ablation and Pacemaker Implantation After Withdrawal of Effective Rate‐Control Medications for Chronic Atrial Fibrillation: Effect on Quality of Life and Exercise Performance. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1999.tb00383.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.