CoChat

Patients' Attitudes Toward Implanted Defibrillator Shocks

AHMAD, MAHA, BLOOMSTEIN, LAUREN, ROELKE, MARC, BERNSTEIN, ALAN D., PARSONNET, VICTOR · 2000 · Pacing and Clinical Electrophysiology
Cited by 149

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

In addition to its beneficial effect on patient survival, the implanted cardioverter defibriliator (ICD) changes a patient's life physically, socially, and psychologically. For improved patient management, it is important to understand the quality‐of‐life changes that accompany this mode of treatment. To this end, 119 patients were surveyed retrospectively and interviewed concurrently regarding their emotional, physical, and behavioral responses to ICD shocks and to the device itself. Most (55%) correctly estimated the total number of shocks they had received within a 10% margin. They found the shocks severe, 79% assigning a score between 3 and 5 on a scale of 1–5. Common descriptions of the shock sensation were a blow to the body or a spasm causing the entire body to jump. Most patients tolerated the shocks as life saving, but 23% dreaded shocks and 5% even said they would rather be without the ICD and take their chances. After a shock, 50% of patients called their physician and 42% continued their daily routine. Thirty percent went to a hospital emergency room or called a rescue service. Sixty‐five percent had no preshock prodromes. Fifty‐four percent were interested in the programmable option of a warning signal prior to a shock, while 31 % preferred no warning. Of the 74% who were advised not to drive after implantation, 29% drove anyway. Five patients were shocked while driving with no resulting accidents. We conclude that most patients find ICD shocks moderately uncomfortable, but they tolerate them because of the lifesaving protection provided by the device.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2000.tb00877.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 10

  1. May CD, 1995, The impart of the im‐plantable cardioverler defibrillator on quality‐of‐life, PACK, 18, 1411
  2. Bernstein AD, 1996, Patients' attitudes to ward implanted‐defibrillalur therapy, PACE, 19, 605
  3. 10.1016/0002-8703(94)90107-4 · DOI
  4. 10.1111/j.1540-8159.1997.tb04817.x · DOI · Paper page
  5. 10.1159/000289032 · DOI · Paper page
  6. 10.3949/ccjm.57.5.441 · DOI · Paper page
  7. Bainger EM, 1995, Perceived quality of life before and after implantation of an internal cardioverter defibrillator, Am J Crit Care, 4, 36, 10.4037/ajcc1995.4.1.36 · DOI
  8. 10.1097/00005082-199002000-00008 · doi:10.1097/00005082-199002000-00008
  9. 10.1016/S0033-3182(91)72112-9 · DOI
  10. 10.1016/S0002-9149(96)00502-4 · DOI

Cited by

See all 149

Metadata

Authors
AHMAD, M., BLOOMSTEIN, L., ROELKE, M., BERNSTEIN, A. D., & PARSONNET, V.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2000-06
Volume
23
Issue
6
Pages
934-938
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2030786785
Cited by
149
References
1
FWCI
2.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Patients' Attitudes Toward Implanted Defibrillator Shocks. https://app.cochat.ai/papers/10.1111/j.1540-8159.2000.tb00877.x
The paper
AHMAD, M., BLOOMSTEIN, L., ROELKE, M., BERNSTEIN, A. D., & PARSONNET, V. (2000). Patients' Attitudes Toward Implanted Defibrillator Shocks. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2000.tb00877.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.