Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 185

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

QRS Duration and Shortening to Predict Clinical Response to Cardiac Resynchronization Therapy in Patients with End‐Stage Heart Failure

MOLHOEK, SANDER G., BAX, JEROEN J., BOERSMA, ERIC, ERVEN, LIESELOT VAN, BOOTSMA, MARIANNE, STEENDIJK, PAUL, VAN DER WALL, ERNST E., SCHALIJ, MARTIN J. · 2004 · Pacing and Clinical Electrophysiology

Abstract

Despite current selection criteria (NYHA Class III–IV, LVEF < 35%, QRS > 120 ms with LBBB), 30% of patients do not benefit from cardiac resynchronization therapy (CRT). The use of QRS duration as selection criteria for CRT has not been evaluated systematically yet. Accordingly, the value of QRS duration at baseline (and reduction in QRS duration after CRT) to predict responders was studied. Patients were evaluated at baseline and after 6 months of CRT for NYHA Class, quality of life score, and 6‐minute walk test. QRS duration was evaluated before, directly after implantation, and after 6 months of CRT. Sixty‐one patients were included; 45 (74%) patients were classified as responders (improvement of NYHA Class, 6‐minute walking distance and quality of life score) and 16 (26%) as nonresponders. QRS duration at baseline was similar between the two groups: 179 ± 30 ms versus 171 ± 32 ms, NS. Directly after implantation, QRS duration was reduced from 179 ± 30 ms to 150 ± 26 ms (P < 0.01) in responders; nonresponders did not exhibit this reduction (171 ± 32 ms vs 160 ± 26 ms, NS). After 6 months of CRT, QRS shortening was only observed in responders (from 179 ± 30 ms to 159 ± 25 ms, P < 0.01). ROC curve analysis showed that a reduction in QRS duration > 10 ms had a high sensitivity (73%) with low specificity (44%); conversely, a > 50 ms reduction in QRS duration was highly specific (88%) but not sensitive (18%) to predict response to CRT. No optimal cutoff value could be defined. QRS duration at baseline is not predictive for response to CRT; responders exhibit a significant reduction in QRS duration after CRT, but individual response varies highly, not allowing adequate selection of responders. (PACE 2004; 27:308–313)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2004.00433.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 185

Metadata

Authors
MOLHOEK, S. G., BAX, J. J., BOERSMA, E., ERVEN, L. V., BOOTSMA, M., STEENDIJK, P., VAN DER WALL, E. E., & SCHALIJ, M. J.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2004-03
Volume
27
Issue
3
Pages
308-313
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W1980914679
Cited by
185
References
1
FWCI
8.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: QRS Duration and Shortening to Predict Clinical Response to Cardiac Resynchronization Therapy in Patients with End‐Stage Heart Failure. https://app.cochat.ai/papers/10.1111/j.1540-8159.2004.00433.x
The paper
MOLHOEK, S. G., BAX, J. J., BOERSMA, E., ERVEN, L. V., BOOTSMA, M., STEENDIJK, P., VAN DER WALL, E. E., & SCHALIJ, M. J. (2004). QRS Duration and Shortening to Predict Clinical Response to Cardiac Resynchronization Therapy in Patients with End‐Stage Heart Failure. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2004.00433.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.