The DOI matches its Crossref record.
Predictive Value of Early Atrial Tachyarrhythmias Recurrence After Circumferential Anatomical Pulmonary Vein Ablation
Abstract
Objective: Radiofrequency (RF) ablation at the ostia of the pulmonary veins (PVs) to cure atrial fibrillation (AF) is often followed by early AF recurrence. The aims of this study were to determine the rate of early atrial tachyarrhythmia as recurrence after circumferential anatomical PV ablation; to evaluate whether the early recurrence of atrial tachyarrhythmias correlates with the long‐term outcome of ablation; and to identify the predictors of early atrial tachyarrhythmias relapse. Methods: We studied 143 consecutive patients who underwent circumferential anatomical PV ablation. We defined early atrial tachyarrhythmias relapse as the recurrence of atrial tachyarrhythmias during the first 3 months after RF ablation. Results: After a mean follow‐up of 18.7 ± 7.2 months, 102/143 patients (71%) were deemed responders to ablation. Atrial tachyarrhythmias relapsed during the first 3 months of follow‐up in 65/143 (46%) patients. Patients without early atrial tachyarrhythmias relapse had a higher probability of long‐term clinical success than patients with early atrial tachyarrhythmias relapse (95% vs 43%, P < 0.0001). However, patients who relapsed within the first month had 45.5% probability of long‐term clinical success. On multivariate analysis, the presence of structural heart disease and the lack of a successful anatomical ablation of all targeted PV were significantly and independently correlated with early atrial tachyarrhythmias relapse. Conclusion: A delayed cure may be expected in almost 50% of patients in whom atrial tachyarrhythmias relapses within the first month after circumferential anatomical PV ablation. The presence of structural heart disease and the lack of a successful anatomical ablation of all targeted PV predict early atrial tachyarrhythmias recurrence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Calkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Metadata
- Authors
- BERTAGLIA, E., STABILE, G., SENATORE, G., ZOPPO, F., TURCO, P., AMELLONE, C., DE SIMONE, A., FAZZARI, M., & PASCOTTO, P.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2005-05
- Volume
- 28
- Issue
- 5
- Pages
- 366-371
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2096848943
- Cited by
- 163
- References
- 0
- FWCI
- 4.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Predictive Value of Early Atrial Tachyarrhythmias Recurrence After Circumferential Anatomical Pulmonary Vein Ablation. https://app.cochat.ai/papers/10.1111/j.1540-8159.2005.09516.x
- The paper
- BERTAGLIA, E., STABILE, G., SENATORE, G., ZOPPO, F., TURCO, P., AMELLONE, C., DE SIMONE, A., FAZZARI, M., & PASCOTTO, P. (2005). Predictive Value of Early Atrial Tachyarrhythmias Recurrence After Circumferential Anatomical Pulmonary Vein Ablation. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2005.09516.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.