Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 158

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Reducing Unnecessary Right Ventricular Pacing with the Managed Ventricular Pacing Mode in Patients with Sinus Node Disease and AV Block

Open access
GILLIS, ANNE M., PÜRERFELLNER, HELMUT, ISRAEL, CARSTEN W., SUNTHORN, HENRI, KACET, SALEM, ANELLI‐MONTI, MICHAEL, TANG, FENG, YOUNG, MARTIN, BORIANI, GIUSEPPE, On behalf of the Medtronic Enrhythm Clinical Study Investigators · 2006 · Pacing and Clinical Electrophysiology

Abstract

Background: Frequent and unnecessary right ventricular apical pacing increases the risk of atrial fibrillation or congestive heart failure. We evaluated a new pacing algorithm, managed ventricular pacing (MVP) which automatically changes modes between AAI/R and DDD/R in patients receiving pacemakers for symptomatic bradycardia. Methods: Patients were randomized to the MVP mode or DDD/R mode for 1 month and then crossed over to the alternate pacing modality for an additional month. On completion of the crossover phase, the pacing mode selected was individualized and patients were followed for an additional 4 months. Results: Of the 129 patients who successfully completed the crossover study, the cumulative percent ventricular pacing was significantly reduced in the MVP mode (median 1.4%) compared to the DDD/R mode (median 89.6%, 94.0% relative reduction; 95% CI 89.3–98.8%, P < 0.001). Patients with sinus node disease (SND, n = 51) when compared to patients with AV block (AVB) (n = 68) experienced a greater reduction in ventricular pacing with the MVP mode compared to the DDD/R mode (median relative reduction 99.1%; 95% CI 97.5–99.9% vs median relative reduction 60.1%; 95% CI 16.7–93.9% P < 0.001). The reduced percent ventricular pacing during MVP was sustained over longer term follow‐up. Conclusions: The majority of patients with a bradycardia indication for cardiac pacing do not require ventricular pacing most of the time. The MVP mode significantly reduces unnecessary right ventricular pacing. This mode benefits even patients with intermittent AVB and is sustained over longer term follow‐up.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2006.00422.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 158

Metadata

Authors
GILLIS, A. M., PÜRERFELLNER, H., ISRAEL, C. W., SUNTHORN, H., KACET, S., ANELLI‐MONTI, M., TANG, F., YOUNG, M., BORIANI, G., & On behalf of the Medtronic Enrhythm Clinical Study Investigators
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2006-07
Volume
29
Issue
7
Pages
697-705
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2115090879
Cited by
158
References
3
FWCI
9.40
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reducing Unnecessary Right Ventricular Pacing with the Managed Ventricular Pacing Mode in Patients with Sinus Node Disease and AV Block. https://app.cochat.ai/papers/10.1111/j.1540-8159.2006.00422.x
The paper
GILLIS, A. M., PÜRERFELLNER, H., ISRAEL, C. W., SUNTHORN, H., KACET, S., ANELLI‐MONTI, M., TANG, F., YOUNG, M., BORIANI, G., & On behalf of the Medtronic Enrhythm Clinical Study Investigators. (2006). Reducing Unnecessary Right Ventricular Pacing with the Managed Ventricular Pacing Mode in Patients with Sinus Node Disease and AV Block. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2006.00422.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.