Percutaneous Lead Implantation Connected to an External Device in Stimulation‐Dependent Patients with Systemic Infection—A Prospective and Controlled Study
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: Permanent pacemaker implantation usually is contraindicated in patients with systemic infection. The aim of the present study was to compare two different techniques of transvenous temporary pacing to bridge the infectious situation until permanent pacemaker implantation under infection‐free conditions is possible. Methods and Results: Forty‐nine patients with systemic infection and hemodynamic‐relevant bradyarrhythmia/asystole were temporarily paced using either a conventional pacing wire/catheter (n = 26, reference group) or a permanent bipolar active pacing lead, which was placed transcutaneously in the right ventricle and connected to an external pacing generator (n = 23, external lead group). In both groups, there were no significant differences in patient characteristics. Whereas the sensing values were almost identical, the median pacing threshold was significantly higher in the reference group (1.0 V vs 0.6 V, P < 0.05). Within comparable duration of pacing (median: 8.2 vs 7.7 days), there were 24 pacing‐related adverse events (including dislocation, resuscitation due to severe bradycardia, or local infection) in the reference group as compared to one event in the external lead group (P < 0.01). None of these complications resulted in cardiac death. Conclusion: Thus, transvenous pacing with active fixation is safe and associated with a significantly lower rate of pacing‐related adverse events as compared to the standard technique of transvenous pacing using a passive external pacing catheter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Systemic Infection Related to Endocarditis on Pacemaker Leads: Clinical Presentation and Management
Klug, D., Lacroix, D., Savoye, C., Goullard, L., Grandmougin, D., Hennequin, J. L., Kacet, S., & Lekieffre, J. (1997) · Circulation · doi:10.1161/01.cir.95.8.2098 · Cited by 593
Research works printed but not linked: 18
- 10.1136/heart.83.6.715 · doi:10.1136/heart.83.6.715
- 10.1016/0735-1097(94)90618-1 · doi:10.1016/0735-1097(94)90618-1
- Hynes JK, 1983, Five‐year experience with temporary pacemaker therapy in the coronary care unit, Mayo Clin Proc, 58, 122
- 10.1016/j.ejcts.2005.02.040 · DOI
- 10.1136/bmj.312.7039.1134 · DOI · Paper page
- 10.1016/0002-9149(82)90505-7 · DOI
- Lang CC, 2005, Hybrid long‐term temporary pacing, J Invasive Cardiol, 17, 338
- 10.1016/S0749-0704(18)30221-5 · DOI
- 10.1046/j.1460-9592.2003.t01-1-00149.x · doi:10.1046/j.1460-9592.2003.t01-1-00149.x
- Winner S, 1989, Clinical problems with temporary pacemakers prior to permanent pacing, J R Coll Physicians Lond, 23, 161
- 10.1136/pgmj.65.762.211 · DOI · Paper page
- 10.1136/bmj.317.7150.79a · doi:10.1136/bmj.317.7150.79a
- 10.1136/pgmj.75.888.577 · doi:10.1136/pgmj.75.888.577
- 10.1016/S0140-6736(97)24026-2 · DOI
- 10.1016/S1885-5857(06)60190-4 · DOI
- 10.1136/pmj.79.934.463 · DOI · Paper page
- 10.1002/clc.4960170109 · doi:10.1002/clc.4960170109
- 10.1097/00003246-200010001-00003 · DOI
Cited by
Habib, G., Lancellotti, P., Antunes, M. J., Bongiorni, M. G., Casalta, J.-P., Del Zotti, F., Dulgheru, R., El Khoury, G., Erba, P. A., Iung, B., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv319 · Cited by 4,997
Kusumoto, F. M., Schoenfeld, M. H., Wilkoff, B. L., Berul, C. I., Birgersdotter-Green, U. M., Carrillo, R., Cha, Y.-M., Clancy, J., Deharo, J.-C., Ellenbogen, K. A., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.09.001 · Cited by 1,199
Baddour, L. M., Epstein, A. E., Erickson, C. C., Knight, B. P., Levison, M. E., Lockhart, P. B., Masoudi, F. A., Okum, E. J., Wilson, W. R., Beerman, L. B., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.192665 · Cited by 1,030
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000628 · Cited by 603
Metadata
- Authors
- BRAUN, M. U., RAUWOLF, T., BOCK, M., KAPPERT, U., BOSCHERI, A., SCHNABEL, A., & STRASSER, R. H.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2006-08
- Volume
- 29
- Issue
- 8
- Pages
- 875-879
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W1999376541
- Cited by
- 105
- References
- 1
- FWCI
- 0.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Percutaneous Lead Implantation Connected to an External Device in Stimulation‐Dependent Patients with Systemic Infection—A Prospective and Controlled Study. https://app.cochat.ai/papers/10.1111/j.1540-8159.2006.00454.x
- The paper
- BRAUN, M. U., RAUWOLF, T., BOCK, M., KAPPERT, U., BOSCHERI, A., SCHNABEL, A., & STRASSER, R. H. (2006). Percutaneous Lead Implantation Connected to an External Device in Stimulation‐Dependent Patients with Systemic Infection—A Prospective and Controlled Study. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2006.00454.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.