Pacemaker Endocarditis: Clinical Features and Management of 60 Consecutive Cases

MASSOURE, PIERRE‐LAURENT, REUTER, SYLVAIN, LAFITTE, STEPHANE, LABORDERIE, JULIEN, BORDACHARD, PIERRE, CLEMENTY, JACQUES, ROUDAUT, RAYMOND · 2007 · Pacing and Clinical Electrophysiology
Cited by 118

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: The incidence of endocarditis related to pacemakers is increasing, while the diagnosis and management remain difficult. The objective of this study was to evaluate the clinical features and management of endocarditis after implantation of pacemakers (PM) or cardioverter defibrillators (ICD). Methods: We analyzed the hospital course of 60 consecutive patients (48 men, mean age 68 ± 12 years) admitted to our center for PM (n = 59) or ICD (n = 1) endocarditis between 1998 and 2004. Results: Fever (78%), asthenia (65%), and local symptoms (35%) were common. Positive cultures were obtained in 53 cases (Staphylococcus 89%). Sixteen patients (27%) had pulmonary embolism. Vegetations (mean size 15.2 ± 8 mm, range 5 to 35 mm) were found in 54 cases (90%), with transthoracic echocardiography in 26 cases (43%), and transesophageal echocardiography (TEE) in 50 cases (89% of the 56 patients who had TEE). Devices were removed surgically (n = 20) or percutaneously (n = 37). In the surgical group, vegetations were larger (17.9 ± 7 mm vs 13.2 ± 7 mm, P = 0.01). After removal, 42 patients (70%) had a new PM. Mortality factors (6 deaths – follow up 3.4 ± 2 years) were the number of vegetations and absence of extraction of the device (P < 0.02). Clinical features and management of the 37 patients with early onset endocarditis (within 1 year after implantation) did not differ from those with late onset. Conclusions: PM endocarditis was essentially staphylococcal. TEE was required for the diagnosis of vegetations. Complete removal of the device is required and associated with a favorable outcome.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2007.00574.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 118

Metadata

Authors
MASSOURE, P., REUTER, S., LAFITTE, S., LABORDERIE, J., BORDACHARD, P., CLEMENTY, J., & ROUDAUT, R.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2007-01
Volume
30
Issue
1
Pages
12-19
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W1983938871
Cited by
118
References
2
FWCI
6.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pacemaker Endocarditis: Clinical Features and Management of 60 Consecutive Cases. https://app.cochat.ai/papers/10.1111/j.1540-8159.2007.00574.x
The paper
MASSOURE, P., REUTER, S., LAFITTE, S., LABORDERIE, J., BORDACHARD, P., CLEMENTY, J., & ROUDAUT, R. (2007). Pacemaker Endocarditis: Clinical Features and Management of 60 Consecutive Cases. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2007.00574.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.