Prevalence and Characterization of Asymptomatic Pacemaker and ICD Lead Perforation on CT
Abstract
Background: Pacemakers and implantable cardiac defibrillators (ICDs) are widely used for the management of cardiac arrhythmias and congestive heart failure (CHF). Acute implantation complication rates range from 3% to 7%. The aim of this study is to describe the incidence of lead perforation on computed tomography (CT), and correlate these findings with electrophysiologic data. Methods: Images of 100 consecutive patients with permanent pacemakers (n = 72) or ICDs (n = 28) who underwent multidetector CTs of the chest were identified. Cases were reviewed by 2 cardiothoracic radiologists, and a third if there was disagreement. Each CT was reviewed for device and fixation type, tip position, and presence of pericardial effusion. Results were correlated with lead impedance and pacing threshold, when available [79% (79/100)]. A cardiac electrophysiologist interpreted device data. Results: All 100 patients had right ventricular leads (58 passive, 42 active) and 61 had right atrial leads (12 passive, 49 active). 15% (15/100) of patients had a lead perforation. Perforation rates were 15% (9/61) for atrial and 6% (6/100) for ventricular leads (P < 0.05, chi square). Four of 28 (14%) right ventricular ICD leads and 2 of 72 (3%) right ventricular pacemaker leads were perforated (P < 0.05, chi square). 12% (6/49) of active right atrial leads, and 25% (3/12) of passive right atrial leads perforated (P = NS, chi square). 7% (3/42) of active right ventricular leads, and 5% (3/58) of passive ventricular leads perforated (P = NS, chi square). Electrophysiologic parameters did not differ significantly between perforated and nonperforated leads. Conclusion: Asymptomatic perforation is a common phenomenon and rarely resulting in electrophysiologic consequences. Atrial leads perforated more frequently than ventricular leads, and ventricular ICD leads perforated more frequently than ventricular pacemaker leads.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Incidence and predictors of cardiac perforation after permanent pacemaker placement
Mahapatra, S., Bybee, K. A., Bunch, T. J., Espinosa, R. E., Sinak, L. J., McGoon, M. D., & Hayes, D. L. (2005) · Heart Rhythm · doi:10.1016/j.hrthm.2005.06.011 · Cited by 300
Delayed Lead Perforation: A Disturbing Trend
KHAN, M. N., JOSEPH, G., KHAYKIN, Y., ZIADA, K. M., & WILKOFF, B. L. (2005) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2005.40003.x · Cited by 215
Delayed Complications Following Pacemaker Implantation
Ellenbogen, K. A., Wood, M. A., & Shepard, R. K. (2002) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2002.01155.x · Cited by 141
Cited by
Kusumoto, F. M., Schoenfeld, M. H., Wilkoff, B. L., Berul, C. I., Birgersdotter-Green, U. M., Carrillo, R., Cha, Y.-M., Clancy, J., Deharo, J.-C., Ellenbogen, K. A., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.09.001 · Cited by 1,199
Lin, Y.-S., Hung, S.-P., Chen, P.-R., Yang, C.-H., Wo, H.-T., Chang, P.-C., Wang, C.-C., Chou, C.-C., Wen, M.-S., Chung, C.-M., et al. (2014) · Medicine · doi:10.1097/md.0000000000000213 · Cited by 58
Metadata
- Authors
- HIRSCHL, D. A., JAIN, V. R., SPINDOLA‐FRANCO, H., GROSS, J. N., & HARAMATI, L. B.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2007-01
- Volume
- 30
- Issue
- 1
- Pages
- 28-32
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W1991475615
- Cited by
- 271
- References
- 3
- FWCI
- 8.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prevalence and Characterization of Asymptomatic Pacemaker and ICD Lead Perforation on CT. https://app.cochat.ai/papers/10.1111/j.1540-8159.2007.00575.x
- The paper
- HIRSCHL, D. A., JAIN, V. R., SPINDOLA‐FRANCO, H., GROSS, J. N., & HARAMATI, L. B. (2007). Prevalence and Characterization of Asymptomatic Pacemaker and ICD Lead Perforation on CT. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2007.00575.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.