Extraction of Transvenous Pacing and ICD Leads

SMITH, MACY C, LOVE, CHARLES J.·2008·Pacing and Clinical Electrophysiology

Abstract

The emergence of pacing and implantable cardioverter‐defibrillator (ICD) systems, along with expanding indications of these devices (e.g., cardiac resynchronization therapy and sudden cardiac death prevention), increasing infection rates, and device recalls have created the need for removing and upgrading these systems due to various reasons. Removing the pulse generator of a system is generally uncomplicated. Chronically implanted transvenous leads, however, adhere to the venous endothelium and endocardial tissues over time due to fibrosis. Removal of such leads can be a significantly complex procedure requiring tools and techniques that free the lead at fibrotic binding sites. In this article, the state‐of‐the‐art tools and techniques that provide a systematic approach to consistently and safely extract these devices will be reviewed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2008.01079.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 167

Metadata

Authors
SMITH, M. C., & LOVE, C. J.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2008-05-27
Volume
31
Issue
6
Pages
736-752
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2108785150
Cited by
167
References
1
FWCI
11.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Extraction of Transvenous Pacing and ICD Leads. https://app.cochat.ai/papers/10.1111/j.1540-8159.2008.01079.x
The paper
SMITH, M. C., & LOVE, C. J. (2008). Extraction of Transvenous Pacing and ICD Leads. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2008.01079.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.