Abstract

Background: Common psychological adjustment difficulties have been identified for groups of implantable cardioverter defibrillator patients, such as those who are young (<50 years old), have been shocked, and are female. Specific aspects and concerns, such as fears of death or shock and body image concerns, that increase the chance of distress, have not been examined in different aged female implantable cardioverter defibrillator (ICD) recipients. The aim of the study was to investigate these areas of adjustment across three age groups of women from multiple centers. Methods: Eighty‐eight female ICD patients were recruited at three medical centers: Shands Hospital at the University of Florida, Brigham and Women's Hospital in Boston, and Royal North Shore Hospital in Sydney, Australia. Women completed individual psychological assessment batteries, measuring the constructs of shock anxiety, death anxiety, and body image concerns. Medical record review was conducted for all patients regarding cardiac illnesses and ICD‐specific data. Results: Multivariate and univariate analyses of variance revealed that younger women reported significantly higher rates of shock and death anxiety (Pillai's F = 3.053, P = 0.018, η 2p= 0.067) and significantly greater body image concerns (Pillai's F = 4.198, P = 0.018, η 2p= 0.090) than middle‐ and older‐aged women. Conclusions: Women under the age of 50 appear to be at greater risk for the development of psychosocial distress associated with shock anxiety, death anxiety, and body image. Clinical‐based strategies and interventions targeting these types of adjustment difficulties in younger women may allow for improved psychosocial and quality of life outcomes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2008.01223.x

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 62

Metadata

Authors
VAZQUEZ, L. D., KUHL, E. A., SHEA, J. B., KIRKNESS, A., LEMON, J., WHALLEY, D., CONTI, J. B., & SEARS, S. F.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2008-11-11
Volume
31
Issue
12
Pages
1528-1534
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2060999424
Cited by
62
References
5
FWCI
2.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Age‐Specific Differences in Women with Implantable Cardioverter Defibrillators: An International Multi Center Study. https://app.cochat.ai/papers/10.1111/j.1540-8159.2008.01223.x
The paper
VAZQUEZ, L. D., KUHL, E. A., SHEA, J. B., KIRKNESS, A., LEMON, J., WHALLEY, D., CONTI, J. B., & SEARS, S. F. (2008). Age‐Specific Differences in Women with Implantable Cardioverter Defibrillators: An International Multi Center Study. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2008.01223.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.