CoChat

Atrial Fibrillation Ablation in Patients with Therapeutic International Normalized Ratios

SCHMIDT, MARTIN, SEGERSON, NATHAN M., MARSCHANG, HARALD, AKOUM, NAZEM, RITTGER, HARALD, CLIFFORD, SARAH M., BRACHMANN, JOHANNES, DACCARETT, MARCOS, MARROUCHE, NASSIR F · 2009 · Pacing and Clinical Electrophysiology
Cited by 60

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Aims: Pulmonary vein antrum isolation (PVAI) plays a pivotal role in the comprehensive treatment of atrial fibrillation (AF). The need for effective anticoagulation bridging following PVAI is associated with significant vascular complication rates and increased costs. We investigated the safety of PVAI in patients with therapeutic international normalized ratios (INR) the day of the procedure. Methods: A case‐control analysis was performed on patients who underwent PVAI with therapeutic INR (>2). Patients with normal preprocedure INR served as controls. The incidence of major and minor hematomas, fistulas, vascular injury, and cardiac perforation or tamponade were catalogued. PVAI was performed under fluoroscopic, electro‐anatomical, and intracardiac echocardiographic guidance, with an open irrigation ablation technique. Results: A total of 194 patients (mean age 64 ± 12) were included; 87 patients underwent PVAI with therapeutic INR (cases) and 107 with normal INR (controls). Persistent AF was more prevalent than paroxysmal AF in the therapeutic INR group. The mean INR for cases was 2.8 ± 0.7 compared to 1.4 ± 0.3 in the control group (P < 0.01). All procedures were completed without acute complications. Two major adverse events were observed, one in each arm. No significant difference in terms of minor (6.5% vs. 5.7%, P = 0.23) or major (0.93% vs. 1.15%, P = 0.49) vascular events or bleeding was detected between the therapeutic INR and the control group. The combined endpoint of major and minor complications did not differ among groups (9.35% vs. 8.05%, P = 0.19). Conclusion: Atrial fibrillation ablation in patients with therapeutic INR on the day of a procedure appears to be safe and feasible. Expensive outpatient anti‐coagulation bridging may be safely avoided in this type of population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2009.02429.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 60

Metadata

Authors
SCHMIDT, M., SEGERSON, N. M., MARSCHANG, H., AKOUM, N., RITTGER, H., CLIFFORD, S. M., BRACHMANN, J., DACCARETT, M., & MARROUCHE, N. F.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2009-07-17
Volume
32
Issue
8
Pages
995-999
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2112721561
Cited by
60
References
2
FWCI
4.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.