Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 396

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Continued Rise in Rates of Cardiovascular Implantable Electronic Device Infections in the United States: Temporal Trends and Causative Insights

VOIGT, ANDREW, SHALABY, ALAA, SABA, SAMIR·2010·Pacing and Clinical Electrophysiology

Abstract

BACKGROUND: Cardiovascular implantable electronic device (CIED) infections have been increasing out of proportion to the number of devices implanted, based on data available through 2003. We investigated recent trends and possible causes of the increasing numbers of CIED infections. METHODS: We analyzed the occurrence of CIED infections and the associated changes in characteristics of CIED recipients, using the National Hospital Discharge Survey database from 1996 through 2006. RESULTS: The number of CIED implantations continued to increase after 2003 from 199,516 in 2004 to 222,940 in 2006, representing a 12% increment. In the same period, the number of CIED infections increased from 8,273 in 2004 to 12,979 in 2006, representing a 57% increment. From 1996 to 2006, comorbid illnesses in recipients of new CIED devices became more prevalent with an increasing percentage of patients with end-organ failures (6.5% in 1996 vs 8.0% in 2006, P < 0.001) and diabetes mellitus (14.5% in 1996 vs 16.5% in 2006, P = 0.005). The proportion of Caucasian recipients also decreased (65.6% in 1996 vs 57.6% in 2006, P < 0.001). During that same period, the number of implanted cardiac resynchronization devices increased dramatically while the age of CIED recipients did not change. CONCLUSION: The number of patients with CIED-related infections in the United States continues to increase out of proportion to the increase in implantation rates. Possible causes for this on-going epidemic include sicker patients with varying racial backgrounds, and more complex procedures. These insights may help improve our ability to best select patients for CIED implantation in "real-life" settings. (PACE 2010; 414-419).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2009.02569.x

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 396

Metadata

Authors
VOIGT, A., SHALABY, A., & SABA, S.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2010-04
Volume
33
Issue
4
Pages
414-419
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2104236761
Cited by
396
References
20
FWCI
11.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Continued Rise in Rates of Cardiovascular Implantable Electronic Device Infections in the United States: Temporal Trends and Causative Insights. https://app.cochat.ai/papers/10.1111/j.1540-8159.2009.02569.x
The paper
VOIGT, A., SHALABY, A., & SABA, S. (2010). Continued Rise in Rates of Cardiovascular Implantable Electronic Device Infections in the United States: Temporal Trends and Causative Insights. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2009.02569.x