CoChat

Adolescents with Implantable Cardioverter Defibrillators: A Patient and Parent Perspective

RAHMAN, BELINDA, MACCIOCCA, IVAN, SAHHAR, MARGARET, KAMBERI, SULEMAN, CONNELL, VANESSA, DUNCAN, RONY E. · 2012 · Pacing and Clinical Electrophysiology
Cited by 57

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background: An implantable cardioverter defibrillator (ICD) is a device used in the treatment of individuals with life‐threatening cardiac conditions. These include genetic disorders such as long QT syndrome, hypertrophic cardiomyopathy, and Brugada syndrome, all of which have the propensity to cause sudden cardiac death. Adults with ICDs consistently report elevated levels of anxiety and depression, as well as negative lifestyle changes associated with the device. Compared to older ICD recipients, young patients face decades of life with the device and the long‐term impact and implications are important to consider. This research explores the experiences of adolescents living with an ICD. Parents of these adolescents were also included to explore the impact on them as the primary caregivers. Methods: A qualitative approach was chosen to explore the lived experience; semistructured interviews with six adolescents and six parents were conducted from which a number of key themes emerged. Results: The experiences described by participants included the restrictions adolescents face, the ICD shock experience, and ongoing challenges post‐ICD implantation. However, both adolescents and parents were able to adjust to life after receiving an ICD and described several benefits associated with having the device. Findings also emerged relating to communication between health professionals and adolescents, and the limitations adolescents impose on themselves post‐ICD implantation. Conclusion: These findings have important implications for clinical practice and may help guide medical management for adolescents with ICDs and their families. (PACE 2012; 35:62–72)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2011.03229.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 57

Metadata

Authors
RAHMAN, B., MACCIOCCA, I., SAHHAR, M., KAMBERI, S., CONNELL, V., & DUNCAN, R. E.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2011-10-03
Volume
35
Issue
1
Pages
62-72
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2142021012
Cited by
57
References
3
FWCI
1.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.