CoChat

Risk Stratification in Wolff‐Parkinson‐White Syndrome: The Correlation Between Noninvasive and Invasive Testing in Pediatric Patients

WACKEL, PHILIP, IRVING, CLAIRE, WEBBER, STEVEN, BEERMAN, LEE, ARORA, GAURAV · 2012 · Pacing and Clinical Electrophysiology
Cited by 60

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Background: In Wolff‐Parkinson‐White (WPW) syndrome, rapid antegrade conduction of atrial tachyarrhythmias can result in ventricular fibrillation and sudden death. Antegrade conduction can be assessed through noninvasive testing or invasive electrophysiology study (EPS). We aimed to determine the correlation between noninvasive testing and EPS in a pediatric WPW population. Methods: All WPW patients <21 years who underwent EPS over a 10‐year period were identified. Noninvasive testing reviewed included electrocardiogram, Holter, and exercise stress test (EST). Patients were classified as low‐risk if preexcitation was lost during any test. EPS data reviewed included antegrade conduction during atrial pacing and atrial fibrillation. Conduction through the accessory pathway (AP) to a cycle length ≤250 ms was considered rapid, otherwise patients were nonrapid. Sensitivity, specificity, positive (PPV), and negative predictive value (NPV) of noninvasive testing to correctly identify nonrapid conduction was calculated. Results: There were 135 EPS. Twenty‐four patients (18%) were classified low‐risk noninvasively. Two of the 24 (8%) had rapid conduction at baseline EPS. The sensitivity, specificity, PPV, and NPV of low‐risk noninvasive testing to predict nonrapid conduction was 22%, 94%, 92%, and 31%, respectively. Sixteen of the 24 had low‐risk EST and none had rapid conduction at baseline EPS. The specificity and PPV of low‐risk EST were 100%. Conclusion: Loss of preexcitation during noninvasive testing had high specificity and PPV for nonrapid antegrade conduction during baseline EPS. Abrupt loss of preexcitation during EST was a highly reliable noninvasive marker of nonrapid AP conduction at baseline in our pediatric WPW patients. (PACE 2012;35:1451–1457)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2012.03518.x

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 60

Metadata

Authors
WACKEL, P., IRVING, C., WEBBER, S., BEERMAN, L., & ARORA, G.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2012-09-14
Volume
35
Issue
12
Pages
1451-1457
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2110089065
Cited by
60
References
8
FWCI
2.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.