CoChat

Assessment of Beat‐by‐Beat Control of Heart Rate by the Autonomic Nervous System: Molecular Biology Techniques Are Necessary, But Not Sufficient

LEVY, MATTHEW N., YANG, TIANEN, WALLICK, DON W. · 1993 · Journal of Cardiovascular Electrophysiology
Cited by 61

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Neural Control of Heart Rate. Vagus nerve activity can change heart rate substantially within one cardiac cycle, and the chronotropic effects decay almost completely within one cardiac cycle after cessation of vagal activity. The ability of the vagus nerves to regulate heart rate beat by beat can be explained in large part by the speed at which the neural signal is transduced to a cardiac response and by the rapidity of the processes that restore the basal heart rate when vagal activity ceases. Currently, the question of whether the cardiac tells can transduce the sympathetic neural signals rapidly enough to implement beatwise regulation is controversial. Emphasis on the speed of the processes that initiate the responses may, however, be misplaced. Instead, the processes that terminate the responses to autonomic neural activity (especially those processes that remove the released neurotransmitters) are probably the main determinants of the ability of the vagal and sympathetic systems to affect beatwise control. The norepinephrine (NE) released from the sympathetic nerve endings is removed from the cardiac tissues much more slowly than is the acetylcholine that is released from the vagal terminals. As a consequence of the potential deleterious effects associated with the slow removal of NE, the cardiac neural control system has evolved such that the sympathetic nerves ordinarily release NE at a slow rate. Hence, changes in sympathetic neural activity can alter cardiac behavior only slightly from beat to beat. Hence, beatwise control of cardiac function would be negligible, regardless of how swiftly the sympathetic nerve impulse is transduced t o a change in cardiac‐performance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.1993.tb01222.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 61

Metadata

Authors
LEVY, M. N., YANG, T., & WALLICK, D. W.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
1993-04
Volume
4
Issue
2
Pages
183-193
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2161428689
Cited by
61
References
1
FWCI
1.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.