Cited by 50Cardiac pacing and defibrillation studiesCardiovascular Syncope and Autonomic DisordersCardiac electrophysiology and arrhythmias

Implantable Cardioverter Defibrillator Utilization Among Device Recipients Presenting Exclusively with Syncope or Near‐Syncope

MILITIANU, ARIE, SALACATA, ABRAHAM, SEIBERT, KAREN, KEHOE, RICHARD, BAGA, JOHN J., MEISSNER, MARC D., PIRES, LUIS A., SCHUGER, CLAUDIO D. +6 more·1997·Journal of Cardiovascular Electrophysiology

Abstract

Introduction Implantable cardioverter defibrillators (ICDs) are occasionally used in presumed high-risk patients with electrocardiographically undocumented syncope, although the incidence of ventricular tachyarrhythmias in this population is not well defined. Methods and results We studied 33 consecutive patients receiving an ICD (67% nonthoracotomy and 70% tiered therapy) after electrophysiologic testing for unmonitored "syncope" (n = 29) or "near-syncope" (n = 4). Atherosclerotic heart disease was present in 24 (73%); mean left ventricular ejection fraction (LVEF) was 0.39 +/- 0.15; and sustained monomorphic ventricular tachycardia (SMVT) was inducible in 18 (55%). Over a median follow-up of 17 months (range 4 to 61), 12 patients (36%) received > or = 1 appropriate ICD discharge triggered by SMVT (cycle length 230 to 375 msec) in 10 and ventricular flutter or fibrillation in 2--without concomitant antiarrhythmic medication in 8 of 12 cases. Inducible SMVT and LVEF 0.35 (P Conclusion In this highly select, multicenter population of ICD recipients with electrocardiographically undocumented syncope, a substantial incidence of appropriate device discharges was observed, particularly in patients with inducible SMVT and LVEF < or = 0.35. These findings support the notion that, in patients with LV dysfunction and inducible SMVT, ventricular tachyarrhythmias are likely to account for episodes of syncope or near-syncope.

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.1997.tb00994.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
MILITIANU, A., SALACATA, A., SEIBERT, K., KEHOE, R., BAGA, J. J., MEISSNER, M. D., PIRES, L. A., SCHUGER, C. D., STEINMAN, R. T., MOSTELLER, R. D., PALTI, A. J., BEN DAVID, J., LESSMEIER, T. J., & LEHMANN, M. H.
Affiliations
  • St. John Hospital & Medical Center (US)
  • Wayne State University (US)
  • Advocate Illinois Masonic Medical Center (US)
  • Summa Health System (US)
  • Carmel Medical Center (IL)
Corresponding author
LEHMANN, MICHAEL H.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
1997-10
Volume
8
Issue
10
Pages
1087-1097
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2112168801
Cited by
50
References
1
Citations by year
2020: 1 · 2018: 1 · 2017: 4 · 2016: 1 · 2015: 1 · 2014: 2 · 2013: 2 · 2012: 2
FWCI
2.16
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Cardiovascular Electrophysiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
  • Health Sciences › Medicine › Surgery › Cardiovascular Syncope and Autonomic Disorders
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
Keywords
implantable cardioverter-defibrillator, syncope, presyncope, monomorphic ventricular tachycardia, left ventricular ejection fraction, ventricular tachyarrhythmia, atherosclerotic heart disease
MeSH terms
Adult, Aged, Aged, 80 and over, Data Collection, Electric Countershock, Electrocardiography, Electric Stimulation Therapy, Female, Follow-Up Studies, Heart Function Tests, Humans, Male, Middle Aged, Syncope, Survival Analysis, Defibrillators, Implantable

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review