Idiopathic Paroxysmal Atrial Fibrillation Induced by a Focal Discharge Mechanism in the Left Superior Pulmonary Vein: Possible Roles of the Ligament of Marshall
The DOI matches its Crossref record.
Abstract
Ablation of Atrial Fibrillation. Introduction: The origin of double potentials inside the left superior pulmonary vein and their relation to the mechanisms of idiopathic paroxysmal focal atrial fibrillation (AF) are unclear. Methods and Results: A total of 40 patients were studied. Group I included 15 patients who underwent radiofrequency catheter ablation of accessory pathway. Double potentials were found inside the left superior pulmonary vein during sinus rhythm in 10 patients and during premature atrial contractions in the remaining five patients. Group II included 25 patients with idiopathic paroxysmal AF. Double potentials were also identified in the left superior pulmonary vein. In 15 patients (Group IIA), the earliest automatic discharge during premature atrial contractions and at the onset of AF was within the left superior pulmonary vein. AF was ablated by radiofrequency energy application at the site registering double potentials. Radiofrequency ablation in the remaining 10 patients failed to terminate AF (Group IIB). The patients in Group UA had significantly more male patients and more frequent premature atrial contractions and atrial tachycardia on 24‐hour Holter recordings prior to the procedure than patients in Group IIB. Conclusions: Double potentials are present at the left superior pulmonary veins in patients with and without a history of AF. The first potential is due to the activation of atrial myocardium and the second is due to the activation of a different muscular structure. Rapid discharge of this structure triggers episodes of paroxysmal AF. Patients with focal AF originating from the left superior pulmonary vein can be identified by Holter recordings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pathophysiological mechanisms of atrial fibrillation: a translational appraisal
Schotten, U., Verheule, S., Kirchhof, P., & Goette, A. (2011) · Physiological Reviews · doi:10.1152/physrev.00031.2009 · Cited by 1,273
“Fractionated electrograms have been reported in the PV-left atrial junction in humans and dogs (261, 528).”
BackgroundTzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Sepehri Shamloo, A., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Europace · doi:10.1093/europace/euae043 · Cited by 634
Autonomic tone variations before the onset of paroxysmal atrial fibrillation
Bettoni, M., & Zimmermann, M. (2002) · Circulation · doi:10.1161/01.cir.0000018443.44005.d8 · Cited by 534
SAITO, T., WAKI, K., & BECKER, A. E. (2000) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2000.tb00068.x · Cited by 310
Tzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Shamloo, A. S., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Heart Rhythm · doi:10.1016/j.hrthm.2024.03.017 · Cited by 298
Metadata
- Authors
- HWANG, C., KARAGUEUZIAN, H. S., & CHEN, P.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 1999-05
- Volume
- 10
- Issue
- 5
- Pages
- 636-648
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2092080421
- Cited by
- 148
- References
- 0
- FWCI
- 7.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Idiopathic Paroxysmal Atrial Fibrillation Induced by a Focal Discharge Mechanism in the Left Superior Pulmonary Vein: Possible Roles of the Ligament of Marshall. https://app.cochat.ai/papers/10.1111/j.1540-8167.1999.tb00240.x
- The paper
- HWANG, C., KARAGUEUZIAN, H. S., & CHEN, P. (1999). Idiopathic Paroxysmal Atrial Fibrillation Induced by a Focal Discharge Mechanism in the Left Superior Pulmonary Vein: Possible Roles of the Ligament of Marshall. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.1999.tb00240.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.