The DOI matches its Crossref record.
Spatially Distributed Dominant Excitation Frequencies Reveal Hidden Organization in Atrial Fibrillation in the Langendorff‐Perfused Sheep Heart
Abstract
Dominant Frequencies Organization in AF Introduction: Atrial fibrillation (AF) is characterized by complex wave propagation, yet periodic excitation suggesting a high degree of organization may be revealed during sustained AF. We provide a systematic quantification of the spatial distribution of dominant frequencies (DFs) of local excitation on the epicardium of the right atrial (RA) free wall and left atrial (LA) appendage of the isolated sheep heart during AF. The data reveal, for the first time, hidden organization, independent of the activation sequences or nature of electrograms. Methods and Results: In 13 Langendorff‐perfused sheep hearts, AF was induced in presence of 0.1 to 0.6 μM acetylcholine. Video movies (potentiometric dye di‐4‐ANEPPS) of the RA and LA (>30,000 and >20,000 pixels, respectively) were obtained at 120 frames/sec and a biatrial electrogram was recorded. Spectral analyses were performed on movies with DF maps constructed. During AF, the activity formed stable discrete domains with uniform DFs within each domain. Acceleration of AF Increased the number of domains (R = 0.81, P < 0.0001) and the DF variance (R = 0.63, P < 0.001), indicating a decrease in organization. Also, the LA was faster and more homogenous, with smaller number of DF domains, compared to the RA (P < 0.00001). Conclusion: In this model, AF is characterized by multiple domains with distinct DFs on the atrial epicardium. The decrease in domain area with increased rate suggests that AF results from high‐frequency impulses that undergo spectral transformations. The LA is generally faster and more organized than the RA, suggesting that the sources for the impulses are localized to the LA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.03.022 · Cited by 2,955
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Self-citation
Metadata
- Authors
- BERENFELD, O., MANDAPATI, R., DIXIT, S., SKANES, A. C., CHEN, J., MANSOUR, M., & JALIFE, J.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2000-08
- Volume
- 11
- Issue
- 8
- Pages
- 869-879
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2158163231
- Cited by
- 178
- References
- 0
- FWCI
- 3.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spatially Distributed Dominant Excitation Frequencies Reveal Hidden Organization in Atrial Fibrillation in the Langendorff‐Perfused Sheep Heart. https://app.cochat.ai/papers/10.1111/j.1540-8167.2000.tb00066.x
- The paper
- BERENFELD, O., MANDAPATI, R., DIXIT, S., SKANES, A. C., CHEN, J., MANSOUR, M., & JALIFE, J. (2000). Spatially Distributed Dominant Excitation Frequencies Reveal Hidden Organization in Atrial Fibrillation in the Langendorff‐Perfused Sheep Heart. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2000.tb00066.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.