The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
From Selective Parasympathetic Modulation of AV Node to Rate Control Therapy
Abstract
INTRODUCTION: In pediatric and congenital heart disease patients, transvenous ICD implantation may be limited secondary to patient size, venous, or cardiac anatomy. Epicardial patches require a thoracotomy, and may lead to a restrictive pericardial process. Because of these issues, we have explored novel ICD configurations. METHODS: Retrospective review at 10 centers implanting ICDs without a transvenous shocking coil or epicardial patches. RESULTS: Twenty-two patients underwent implant at a mean age of 8.9 years (range: 0.3-43.5), with a mean weight of 25.5 kg (range: 5.2-70). Diagnoses included complex CHD, intracardiac tumors, cardiomyopathy, idiopathic VT, LV noncompaction, and long QT syndrome. Three configurations were used: subcutaneous array, a transvenous design ICD lead placed on the epicardium, or a transvenous design ICD lead placed subcutaneously. Difficulties were found at implant in 8 patients: 4 had difficulty inducing VT/VF, and 4 had high DFTs. Over a mean follow-up of 2.2 years (range: 0.2-10.5), 7 patients had appropriate shocks. Inappropriate shocks occurred in 4 patients. System revisions were required in 7 patients: 2 generator changes (in 1 patient), 3 pace-sense lead replacement, 1 additional subcutaneous coil placement due to increased DFT, 1 upgrade to a transvenous system, and 1 revision to epicardial patch system. CONCLUSIONS: ICD implantation can be performed without epicardial patches or transvenous high-energy leads in this population, using individualized techniques. This will allow ICD use in patients who have intracardiac shunting or are deemed too small for transvenous ICD leads. The long-term outcome and possible complications are as yet unknown in this population, and they should be monitored closely with follow-up DFTs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Silka, M. J., Hardy, B. G., Menashe, V. D., & Morris, C. D. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00187-9 · Cited by 560
Cited by
Khairy, P., Van Hare, G. F., Balaji, S., Berul, C. I., Cecchin, F., Cohen, M. I., Daniels, C. J., Deal, B. J., Dearani, J. A., Groot, N. D., et al. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.05.009 · Cited by 709
Hypoplastic Left Heart Syndrome
Feinstein, J. A., Benson, D. W., Dubin, A. M., Cohen, M. S., Maxey, D. M., Mahle, W. T., Pahl, E., Villafañe, J., Bhatt, A. B., Peng, L. F., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.09.022 · Cited by 503
Atrial Fibrillation and Diabetes Mellitus
Wang, A., Green, J. B., Halperin, J. L., & Piccini, J. P. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.07.020 · Cited by 400
Berul, C. I., Van Hare, G. F., Kertesz, N. J., Dubin, A. M., Cecchin, F., Collins, K. K., Cannon, B. C., Alexander, M. E., Triedman, J. K., Walsh, E. P., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.01.033 · Cited by 399
Arrhythmias in Adult Patients With Congenital Heart Disease
Walsh, E. P., & Cecchin, F. (2007) · Circulation · doi:10.1161/circulationaha.105.592410 · Cited by 398
Metadata
- Authors
- BILLETTE, J., & LAVALLÉE, M.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2005-12
- Volume
- 16
- Issue
- 12
- Pages
- 1368-1369
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2068267903
- Cited by
- 222
- References
- 1
- FWCI
- 10.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: From Selective Parasympathetic Modulation of AV Node to Rate Control Therapy. https://app.cochat.ai/papers/10.1111/j.1540-8167.2005.00271.x
- The paper
- BILLETTE, J., & LAVALLÉE, M. (2005). From Selective Parasympathetic Modulation of AV Node to Rate Control Therapy. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2005.00271.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.