Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 200

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Cerebral Diffusion‐Weighted Magnetic Resonance Imaging: A Tool to Monitor the Thrombogenicity of Left Atrial Catheter Ablation

Open access
LICKFETT, LARS, HACKENBROCH, MATTHIAS, LEWALTER, THORSTEN, SELBACH, STEPHANIE, SCHWAB, JÖRG O., YANG, ALEXANDER, BALTA, OSMAN, SCHRICKEL, JAN, BITZEN, ALEXANDER, LÜDERITZ, BERNDT, SOMMER, TORSTEN · 2006 · Journal of Cardiovascular Electrophysiology

Abstract

Introduction: Cerebral embolism and stroke are feared complications of left atrial catheter ablation such as pulmonary vein (PV) ablation. In order to assess the thrombogenicity of left atrial catheter ablation, knowledge of both clinically evident as well as silent cerebral embolism is important. The aim of the current study was to examine the use of diffusion‐weighted magnetic resonance imaging (DW‐MRI) for detection of cerebral embolism, apparent as well as silent, caused by PV catheter ablation. Methods and Results: Twenty consecutive patients without structural heart disease undergoing lasso catheter‐guided ostial PV ablation using an irrigated‐tip ablation catheter were studied. Cerebral MRI including DW single‐shot spin echo echoplanar, turbo fluid attenuated inversion recovery, and T2‐weighted turbo spin echo sequences were performed the day after the ablation procedure. Ten patients also underwent preprocedure cerebral MRI. All ablation procedures were performed without acute complications. A mean of 3.2 ± 0.6 PVs were ablated per patient. No patient had neurological symptoms following the procedure. In 2 of 20 patients (10%), DW‐MRI revealed new embolic lesions, which were located in the right periventricular white matter in one and in the left temporal lobe in the other patient. There was no statistically significant difference in age, history of hypertension, left atrial volume, and procedure duration between the 2 patients with and the 18 patients without cerebral embolism following AF ablation. Conclusion: This is the first study using highly sensitive DW‐MRI of the brain to detect asymptomatic cerebral embolism after left atrial catheter ablation. Even small, clinically silent, embolic lesions can be demonstrated with this technique. DW‐MRI can be used to monitor and compare the thrombogenicity of different AF ablation approaches.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.2005.00279.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 200

Metadata

Authors
LICKFETT, L., HACKENBROCH, M., LEWALTER, T., SELBACH, S., SCHWAB, J. O., YANG, A., BALTA, O., SCHRICKEL, J., BITZEN, A., LÜDERITZ, B., & SOMMER, T.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2006-01
Volume
17
Issue
1
Pages
1-7
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2126106942
Cited by
200
References
1
FWCI
11.46
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cerebral Diffusion‐Weighted Magnetic Resonance Imaging: A Tool to Monitor the Thrombogenicity of Left Atrial Catheter Ablation. https://app.cochat.ai/papers/10.1111/j.1540-8167.2005.00279.x
The paper
LICKFETT, L., HACKENBROCH, M., LEWALTER, T., SELBACH, S., SCHWAB, J. O., YANG, A., BALTA, O., SCHRICKEL, J., BITZEN, A., LÜDERITZ, B., & SOMMER, T. (2006). Cerebral Diffusion‐Weighted Magnetic Resonance Imaging: A Tool to Monitor the Thrombogenicity of Left Atrial Catheter Ablation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2005.00279.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.