Intracardiac Ultrasound Detection of Thrombus on Transseptal Sheath: Incidence, Treatment, and Prevention
The DOI matches its Crossref record.
Abstract
Background: Transseptal (TS) catheterization is used for left atrial (LA) ablation procedures and a major risk is thromboembolism. The purpose of this study was to assess (1) the value of intracardiac ultrasound (ICUS) monitoring during LA ablation procedures, and (2) a new technique to reduce the risk of thrombus formation. Methods and Results: One hundred and eighty consecutive patients underwent TS catheterization under ICUS guidance with two sheaths for atrial fibrillation ablation and one for other LA procedures. Group I included the initial 90 patients in whom TS sheaths were flushed with a standard 2 U/cc concentration of heparin; group II consisted of the next 90 patients in whom sheaths were flushed with 1,000 U/cc concentration. All patients received bolus and infusion of heparin to maintain ACT between 250–300 seconds. ICUS was monitored throughout. In group I, echodense material at the tip of the sheath consistent with thrombus was observed on ICUS in 8 of 90 patients (9%) within 5–15 minutes of entering the LA. In group II, only 1 of 90 patient (1%) demonstrated thrombus (P < 0.001). There were no significant clinical differences in group I patients with and without thrombus. In all nine patients, the clot was removed with vigorous aspiration. No patients suffered a neurological event. Conclusion: Thrombus formation on TS sheath, detected by ICUS, may be more common than expected despite adequate anticoagulation. Using a higher concentration of heparin for the TS system before deployment reduced the risk. The thrombus was retrieved with aspiration without the need to abort the procedure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Calkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Metadata
- Authors
- MALEKI, K., MOHAMMADI, R., HART, D., COTIGA, D., FARHAT, N., & STEINBERG, J. S.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2005-06
- Volume
- 16
- Issue
- 6
- Pages
- 561-565
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2114166512
- Cited by
- 102
- References
- 0
- FWCI
- 3.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intracardiac Ultrasound Detection of Thrombus on Transseptal Sheath: Incidence, Treatment, and Prevention. https://app.cochat.ai/papers/10.1111/j.1540-8167.2005.40686.x
- The paper
- MALEKI, K., MOHAMMADI, R., HART, D., COTIGA, D., FARHAT, N., & STEINBERG, J. S. (2005). Intracardiac Ultrasound Detection of Thrombus on Transseptal Sheath: Incidence, Treatment, and Prevention. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2005.40686.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.