Idiopathic Left Ventricular Tachycardia Originating from the Mitral Annulus
The DOI matches its Crossref record.
Abstract
Background: Radiofrequency catheter ablation (RFCA) can eliminate most idiopathic repetitive monomorphic ventricular tachycardias (RMVTs) originating from the right and left ventricular outflow tracts (RVOT, LVOT). Here, we describe the electrophysiological (EP) findings of a new variant of RMVT originating from the mitral annulus (MAVT). Methods and Results: MAVT was identified in 35 patients out of 72 consecutive left ventricular RMVTs from May 2000 to June 2004. All patients underwent an EP study and RFCA. The sites of origin of the MAVT were grouped into four groups according to the successful ablation sites around the mitral annulus. Group I included the anterior sites (n = 11), group II the anterolateral sites (n = 9), group III the lateral sites (n = 6), and group IV the posterior sites (n = 9). The MAVTs were a wide QRS tachycardia with a delta wave‐like beginning of the QRS complex. The transitional zone of the R wave occurred between V1‐V2 in all cases. The 12‐lead electrocardiogram (ECG) pattern might reflect the site of the origin of MAVTs around the mitral annulus. We proposed an algorithm for predicting the site of the focus and the tactics needed for successful RFCA of the MAVT. Conclusions: We described the EP findings of the new variant of RMVT, MAVT. Most MAVTs could be eliminated by RF applications to the endocardial mitral annulus using our proposed tactics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Priori, S. G., Blomström-Lundqvist, C., Mazzanti, A., Blom, N., Borggrefe, M., Camm, J., Elliott, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv316 · Cited by 3,893
(2015) · Europace · doi:10.1093/europace/euv319 · Cited by 1,592
EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Della Bella, P., Hindricks, G., Jaïs, P., Josephson, M. E., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.030 · Cited by 770
2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2019) · EP Europace · doi:10.1093/europace/euz132 · Cited by 475
2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2019.03.002 · Cited by 431
Metadata
- Authors
- KUMAGAI, K., YAMAUCHI, Y., TAKAHASHI, A., YOKOYAMA, Y., SEKIGUCHI, Y., WATANABE, J., IESAKA, Y., SHIRATO, K., & AONUMA, K.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2005-06-07
- Volume
- 16
- Issue
- 10
- Pages
- 1029-1036
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W1973604048
- Cited by
- 104
- References
- 0
- FWCI
- 2.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Idiopathic Left Ventricular Tachycardia Originating from the Mitral Annulus. https://app.cochat.ai/papers/10.1111/j.1540-8167.2005.40749.x
- The paper
- KUMAGAI, K., YAMAUCHI, Y., TAKAHASHI, A., YOKOYAMA, Y., SEKIGUCHI, Y., WATANABE, J., IESAKA, Y., SHIRATO, K., & AONUMA, K. (2005). Idiopathic Left Ventricular Tachycardia Originating from the Mitral Annulus. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2005.40749.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.