Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 244

The DOI matches its Crossref record.

Left Mitral Isthmus Ablation Associated with PV Isolation: Long‐Term Results of a Prospective Randomized Study

FASSINI, GAETANO, RIVA, STEFANIA, CHIODELLI, ROBERTA, TREVISI, NICOLA, BERTI, MARCO, CARBUCICCHIO, CORRADO, MACCABELLI, GIUSEPPE, GIRALDI, FRANCESCO, BELLA, PAOLO DELLA · 2005 · Journal of Cardiovascular Electrophysiology

Abstract

Background: The deployment of an ablation line connecting the left inferior PV to the mitral annulus (mitral isthmus line [MIL]) enhances the efficacy of pulmonary vein disconnection (PVD) in preventing atrial fibrillation (AF) recurrences. Objectives: To investigate the long‐term effect of the additional linear lesion in a prospective randomized study. Methods: One hundred and eighty‐seven patients (37 females, mean age: 55 ± 11 years) with paroxysmal (126) or persistent (61 patients) AF, were prospectively randomized into two groups: PVD (group A, 92 patients) or PVD combined with MIL (group B, 95 patients), performed by means of an irrigated‐tip ablation catheter. Results: Successful disconnection of all PVs was achieved in all patients. A bidirectional block (BB) along the left atrial isthmus was obtained in 72 of 95 (76%) patients in group B, most of whom required additional RF pulses from within the distal CS. A transient ischemic attack occurred in 1 patient of group A, and a cardiac tamponade occurred in 1 patient of group B. At 1 year, 53 ± 5% (group A) and 71 ± 5% (group B) remained arrhythmia free (P = 0.01); subgroup analysis highlights a higher improvement among patients with persistent AF (74 ± 9% vs 36 ± 9%; P < 0.01) than what was observed in paroxysmal AF (76 ± 6% vs 62 ± 6%; P < 0.05); antiarrhythmic drugs were continued in 56% and 50%, respectively, in groups A and B (P = ns). Conclusions: The addition of mitral isthmus line to the PV disconnection allows a significant improvement of sinus rhythm maintenance rate, particularly in patients with persistent AF, without the risk for major complications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.2005.50192.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 244

Metadata

Authors
FASSINI, G., RIVA, S., CHIODELLI, R., TREVISI, N., BERTI, M., CARBUCICCHIO, C., MACCABELLI, G., GIRALDI, F., & BELLA, P. D.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2005-09-14
Volume
16
Issue
11
Pages
1150-1156
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W1976728175
Cited by
244
References
0
FWCI
7.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Left Mitral Isthmus Ablation Associated with PV Isolation: Long‐Term Results of a Prospective Randomized Study. https://app.cochat.ai/papers/10.1111/j.1540-8167.2005.50192.x
The paper
FASSINI, G., RIVA, S., CHIODELLI, R., TREVISI, N., BERTI, M., CARBUCICCHIO, C., MACCABELLI, G., GIRALDI, F., & BELLA, P. D. (2005). Left Mitral Isthmus Ablation Associated with PV Isolation: Long‐Term Results of a Prospective Randomized Study. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2005.50192.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.