Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 227

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Initial Experience in the Use of Integrated Electroanatomic Mapping with Three‐Dimensional MR/CT Images to Guide Catheter Ablation of Atrial Fibrillation

DONG, JUN, DICKFELD, TIMM, DALAL, DARSHAN, CHEEMA, AAMIR, VASAMREDDY, CHANDRASEKHAR R., HENRIKSON, CHARLES A., MARINE, JOSEPH E., HALPERIN, HENRY R., BERGER, RONALD D., LIMA, JOAO A.C., BLUEMKE, DAVID A., CALKINS, HUGH·2006·Journal of Cardiovascular Electrophysiology

Abstract

Introduction: No prior studies have reported the use of integrated electroanatomic mapping with preacquired magnetic resonance/computed tomographic (MR/CT) images to guide catheter ablation of atrial fibrillation (AF) in a series of patients. Methods and Results: Sixteen consecutive patients with drug‐refractory AF underwent catheter ablation under the guidance of a three‐dimensional (3D) electroanatomic mapping system (Carto, Biosense Webster, Inc., Diamond Bar, CA, USA). Gadolinium‐enhanced MR (n = 8) or contrast‐enhanced high‐resolution CT (n = 8) imaging was performed within 1 day prior to the ablation procedures. Using a novel software package (CartoMerge, Biosense Webster, Inc.), the left atrium (LA) with pulmonary veins (PVs) was segmented and extracted for image registration. The segmented 3D MR/CT LA reconstruction was accurately registered to the real‐time mapping space with a combination of landmark registration and surface registration. The registered 3D MR/CT LA reconstruction was successfully used to guide deployment of RF applications encircling the PVs. Upon completion of the circumferential lesions around the PVs, 32% of the PVs were electrically isolated. Guided by a circular mapping catheter, the remaining PVs were disconnected from the LA using a segmental approach. The distance between the surface of the registered 3D MR/CT LA reconstruction and multiple electroanatomic map points was 3.05 ± 0.41 mm. No complications were observed. Conclusions: Three‐dimensional MR/CT images can be successfully extracted and registered to anatomically guided clinical AF ablations. The display of detailed and accurate anatomic information during the procedure enables tailored RF ablation to individual PV and LA anatomy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.2006.00425.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 227

Metadata

Authors
DONG, J., DICKFELD, T., DALAL, D., CHEEMA, A., VASAMREDDY, C. R., HENRIKSON, C. A., MARINE, J. E., HALPERIN, H. R., BERGER, R. D., LIMA, J. A. C., BLUEMKE, D. A., & CALKINS, H.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2006-02-28
Volume
17
Issue
5
Pages
459-466
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2168729437
Cited by
227
References
1
FWCI
23.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Initial Experience in the Use of Integrated Electroanatomic Mapping with Three‐Dimensional MR/CT Images to Guide Catheter Ablation of Atrial Fibrillation. https://app.cochat.ai/papers/10.1111/j.1540-8167.2006.00425.x
The paper
DONG, J., DICKFELD, T., DALAL, D., CHEEMA, A., VASAMREDDY, C. R., HENRIKSON, C. A., MARINE, J. E., HALPERIN, H. R., BERGER, R. D., LIMA, J. A. C., BLUEMKE, D. A., & CALKINS, H. (2006). Initial Experience in the Use of Integrated Electroanatomic Mapping with Three‐Dimensional MR/CT Images to Guide Catheter Ablation of Atrial Fibrillation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2006.00425.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.