CoChat

Frequency Mapping of the Pulmonary Veins in Paroxysmal Versus Permanent Atrial Fibrillation

Open access
SANDERS, PRASHANTHAN, NALLIAH, CHRISHAN J., DUBOIS, RÉMI, TAKAHASHI, YOSHIHIDE, HOCINI, MÉLÈZE, ROTTER, MARTIN, ROSTOCK, THOMAS, SACHER, FRÉDERIC, HSU, LI‐FERN, JÖNSSON, ANDERS, O'NEILL, MARK D., JAÏS, PIERRE, HAÏSSAGUERRE, MICHEL · 2006 · Journal of Cardiovascular Electrophysiology
Cited by 79

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Introduction: The pulmonary veins (PVs) are a dominant source of triggers initiating atrial fibrillation (AF). While recent evidence implicates these structures in the maintenance of paroxysmal AF, their role in permanent AF is not known. The current study aims to compare the contribution of PV activity to the maintenance of paroxysmal and permanent AF. Methods and Results: Thirty‐four patients with paroxysmal AF (n = 20) or permanent AF (n = 14) undergoing ablation were studied. Prior to ablation, 32 seconds of electrograms were acquired from each PV and the coronary sinus (CS). The frequency of activity of each PV and CS was defined as the highest amplitude frequency on spectral analysis. The effects of ablation on the AF cycle length (AFCL) and frequency and on AF termination were determined. Significant differences were observed between paroxysmal and permanent AF. Paroxysmal AF demonstrates higher frequency PV activity (11.0 ± 3.1 vs 8.8 ± 3.0 Hz; P = 0.0003) but lower CS frequency (5.8 ± 1.2 vs 6.9 ± 1.4 Hz; P = 0.01) and longer AFCL (182 ± 17 vs 158 ± 21 msec; P = 0.002), resulting in greater PV to atrial frequency gradient (7.2 ± 2.2 vs 4.2 ± 2.9 Hz; P = 0.006). PV isolation in paroxysmal AF resulted in a greater decrease in atrial frequency (1.0 ± 0.7 vs −0.05 ± 0.4 Hz; P < 0.0001), greater prolongation of the AFCL (49 ± 35 vs 5 ± 6 msec; P < 0.0001), and more frequent AF termination (11/20 vs 0/14; P = 0.0007) compared to permanent AF. Conclusion: Paroxysmal AF is associated with higher frequency PV activity and lesser CS frequency compared to permanent AF. Isolation of the PVs had a greater impact on the fibrillatory process in paroxysmal AF compared to permanent AF, suggesting that while the PVs have a role in maintaining paroxysmal AF, these structures independently contribute less to the maintenance of permanent AF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.2006.00546.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 79

Metadata

Authors
SANDERS, P., NALLIAH, C. J., DUBOIS, R., TAKAHASHI, Y., HOCINI, M., ROTTER, M., ROSTOCK, T., SACHER, F., HSU, L., JÖNSSON, A., O'NEILL, M. D., JAÏS, P., & HAÏSSAGUERRE, M.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2006-07-25
Volume
17
Issue
9
Pages
965-972
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2024308969
Cited by
79
References
1
FWCI
4.59
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.