Spontaneous Pulmonary Vein Firing in Man: Relationship to Tachycardia‐Pause Early Afterdepolarizations and Triggered Arrhythmia in Canine Pulmonary Veins In Vitro

PATTERSON, EUGENE, JACKMAN, WARREN M., BECKMAN, KAREN J., LAZZARA, RALPH, LOCKWOOD, DEBORAH, SCHERLAG, BENJAMIN J., WU, RICHARD, PO, SUNNY · 2007 · Journal of Cardiovascular Electrophysiology
Cited by 120

The DOI matches its Crossref record.

Abstract

Introduction: Rapid firing originating within pulmonary veins (PVs) initiates atrial fibrillation (AF). The following studies were performed to evaluate spontaneous PV firing in patients with AF to distinguish focal versus reentrant mechanisms. Methods: Intracardiac recordings were obtained in 18 patients demonstrating paroxysmal AF. Microelectrode (ME) recordings were obtained from superfused canine PV sleeves (N = 48). Results: Spontaneous PV firing (566 ± 16 bpm; 127 ± 6 ms cycle length) giving rise to AF (52 episodes) was observed. Tachycardia‐pause initiation was present in 132 of 200 episodes of rapid PV firing and 34 of 52 AF episodes. The pause cycle length preceding PV firing was 1,039 ± 86 ms following tachycardia (420 ± 40 ms cycle length). The remaining episodes were initiated following a 702 ± 32 ms pause during sinus rhythm (588 ± 63 ms). Spontaneous firing recorded with a multipolar mapping catheter did not detect electrical activity bridging the diastolic interval between the initial ectopic and preceding post‐pause sinus beat. Tachycardia‐pause initiated PV firing (138 ± 7 ms coupling interval) in patients correlated with tachycardia‐pause enhanced isometric force, early afterdepolarization (EAD) amplitude, and triggered firing within canine PVs. Rapid firing (1,172 ± 134 bpm; 51 ± 8 ms cycle length) following an abbreviated coupling interval (69 ± 12 ms) was initiated in 13 of 18 canine PVs following tachycardia‐pause pacing during norepinephrine + acetylcholine superfusion. Stimulation selectively activating local autonomic nerve terminals facilitated tachycardia‐pause triggered firing in canine PVs (5 of 15 vs 0 of 15; P < 0.05). Conclusions: The studies demonstrate (1) tachycardia‐pause initiation of rapid, short‐coupled PV firing in AF patients and (2) tachycardia‐pause facilitation of isometric force, EAD formation, and autonomic‐dependent triggered firing within canine PVs, suggestive of a common arrhythmia mechanism.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.2007.00909.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 120

Metadata

Authors
PATTERSON, E., JACKMAN, W. M., BECKMAN, K. J., LAZZARA, R., LOCKWOOD, D., SCHERLAG, B. J., WU, R., & PO, S.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2007-07-26
Volume
18
Issue
10
Pages
1067-1075
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2049043030
Cited by
120
References
0
FWCI
5.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Spontaneous Pulmonary Vein Firing in Man: Relationship to Tachycardia‐Pause Early Afterdepolarizations and Triggered Arrhythmia in Canine Pulmonary Veins In Vitro. https://app.cochat.ai/papers/10.1111/j.1540-8167.2007.00909.x
The paper
PATTERSON, E., JACKMAN, W. M., BECKMAN, K. J., LAZZARA, R., LOCKWOOD, D., SCHERLAG, B. J., WU, R., & PO, S. (2007). Spontaneous Pulmonary Vein Firing in Man: Relationship to Tachycardia‐Pause Early Afterdepolarizations and Triggered Arrhythmia in Canine Pulmonary Veins In Vitro. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2007.00909.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.