CoChat

Differentiating Atrioventricular Nodal Reentrant Tachycardia from Junctional Tachycardia: Novel Application of the Delta H‐A Interval

SRIVATHSAN, KOMANDOOR, GAMI, APOOR S., BARRETT, RENEE, MONAHAN, KRISTI, PACKER, DOUGLAS L., ASIRVATHAM, SAMUEL J. · 2008 · Journal of Cardiovascular Electrophysiology
Cited by 59

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Introduction: Junctional tachycardia (JT) and atrioventricular nodal reentrant tachycardia (AVNRT) can be difficult to differentiate. Yet, the two arrhythmias require distinct diagnostic and therapeutic approaches. We explored the utility of the delta H‐A interval as a novel technique to differentiate these two tachycardias. Methods: We included 35 patients undergoing electrophysiology study who had typical AVNRT, 31 of whom also had JT during slow pathway ablation, and four of whom had spontaneous JT during isoproterenol administration. We measured the H‐A interval during tachycardia (H‐A T) and during ventricular pacing (H‐A P) from the basal right ventricle. Interobserver and intraobserver reliability of measurements was assessed. Ventricular pacing was performed at approximately the same rate as tachycardia. The delta H‐A interval was calculated as the H‐A P minus the H‐A T. Results: There was excellent interobserver and intraobserver agreement for measurement of the H‐A interval. The average delta H‐A interval was −10 ms during AVNRT and 9 ms during JT (P < 0.00001). For the diagnosis of JT, a delta H‐A interval ≥ 0 ms had the sensitivity of 89%, specificity of 83%, positive predictive value of 84%, and negative predictive value of 88%. The delta H‐A interval was longer in men than in women with JT, but no gender‐based differences were seen with AVNRT. There was no difference in the H‐A interval based on age ≤ 60 years. Conclusion: The delta H‐A interval is a novel and reproducibly measurable interval that aids the differentiation of JT and AVNRT during electrophysiology studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.2007.00961.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
SRIVATHSAN, K., GAMI, A. S., BARRETT, R., MONAHAN, K., PACKER, D. L., & ASIRVATHAM, S. J.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2007-10-25
Volume
19
Issue
1
Pages
1-6
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2119733213
Cited by
59
References
2
FWCI
4.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.