CoChat

Real‐Time Three‐Dimensional Echocardiography Permits Quantification of Left Ventricular Mechanical Dyssynchrony and Predicts Acute Response to Cardiac Resynchronization Therapy

MARSAN, NINA AJMONE, BLEEKER, GABE B., YPENBURG, CLAUDIA, GHIO, STEFANO, VAN DE VEIRE, NICO R., HOLMAN, EDUARD R., VAN DER WALL, ERNST E., TAVAZZI, L., SCHALIJ, MARTIN J., BAX, JEROEN J. · 2008 · Journal of Cardiovascular Electrophysiology
Cited by 140

The DOI matches its Crossref record.

Abstract

Objective: To evaluate the value of real‐time three‐dimensional echocardiography (RT3DE) to predict acute response to cardiac resynchronization therapy (CRT). Methods: Sixty consecutive heart failure patients scheduled for CRT were included. RT3DE was performed before and within 48 hours after pacemaker implantation to calculate both left ventricular (LV) volumes and LV dyssynchrony. LV dyssynchrony was defined as the standard deviation of the time taken to reach the minimum systolic volume for 16 LV segments (referred to as the systolic dyssynchrony index, SDI). Patients were subsequently divided into acute responders or nonresponders, based on a reduction ≥ 15% in LV end‐systolic volume immediately after CRT. Results: Four patients (7%) were excluded from further analysis because of either suboptimal apical acquisitions or significant translation artifacts. Out of the remaining 56 patients, 35 patients (63%) were classified as acute responders. Baseline characteristics were similar between responders and nonresponders, except for the SDI, which was larger in responders. Moreover, responders demonstrated a significant reduction of SDI immediately after CRT (from 9.7 ± 4.1% to 3.6 ± 1.8%, P < 0.0001), whereas SDI did not change in nonresponders (3.4 ± 1.8% vs 3.1 ± 1.1%, NS). ROC curve analysis revealed that a cut‐off value for SDI of 5.6% yielded a sensitivity of 88% with a specificity of 86% to predict acute echocardiographic response to CRT (AUC 0.96). Conclusion: RT3DE is highly predictive for acute response to CRT (sensitivity 88% and specificity 86%). In addition, RT3DE allows assessment of changes in LV volumes and LV ejection fraction before and after CRT implantation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.2007.01056.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
MARSAN, N. A., BLEEKER, G. B., YPENBURG, C., GHIO, S., VAN DE VEIRE, N. R., HOLMAN, E. R., VAN DER WALL, E. E., TAVAZZI, L., SCHALIJ, M. J., & BAX, J. J.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2007-12-20
Volume
19
Issue
4
Pages
392-399
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2083948913
Cited by
140
References
0
FWCI
11.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.