Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 290

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Cardiac Resynchronization Therapy (and Multisite Pacing) in Pediatrics and Congenital Heart Disease: Five Years Experience in a Single Institution

CECCHIN, FRANK, FRANGINI, PATRICIA A., BROWN, DAVID W., FYNN‐THOMPSON, FRANCIS, ALEXANDER, MARK E., TRIEDMAN, JOHN K., GAUVREAU, KIMBERLEE, WALSH, EDWARD P., BERUL, CHARLES I. · 2009 · Journal of Cardiovascular Electrophysiology

Abstract

Introduction: Clinical evidence supports the use of cardiac resynchronization therapy (CRT) in adults with heart failure, but experience in pediatrics and congenital heart disease (CHD) is limited in terms of patient numbers and follow‐up. We sought to determine the functional assessment and clinical outcomes in pediatric and CHD CRT patients followed uniformly at one institution. Methods: Retrospective review of 60 consecutive patients who underwent CRT between 2002 and 2007. Results: At implantation, median age was 15.0 years (5 months to 47 years). Overall, 46 patients had CHD (77%) and 14 had dilated cardiomyopathy. Prior to CRT, 92% were on heart failure treatment drugs and 55% had pacemakers. Median follow‐up time was 0.7 years (1 day–5.3 years). Median QRS width decreased from 149 to 120 ms (P < 0.001). Median ejection fraction (EF) increased from 36% to 42% (P < 0.001) and improvement was particularly evident in the group with CHD. Of note, 8 of 13 patients with single ventricle morphology had a “strong CRT response,” defined as either an improvement of 2–3 ordinal points in NYHA classification and/or increased ventricular function by ≥ 10 EF units. Overall, an improvement in functional status was observed in 39 of 45 patients (87%) with sufficient follow‐up data. Conclusions: Children and CHD patients treated with CRT have acute improvement in ventricular function, but implantation may require individualized planning and unconventional approaches. Future important goals include preimplant determination of CRT responders in pediatric and CHD patients, optimizing lead placement and programing, as well as long‐term CRT device management issues.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.2008.01274.x

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 290

Metadata

Authors
CECCHIN, F., FRANGINI, P. A., BROWN, D. W., FYNN‐THOMPSON, F., ALEXANDER, M. E., TRIEDMAN, J. K., GAUVREAU, K., WALSH, E. P., & BERUL, C. I.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2008-12-29
Volume
20
Issue
1
Pages
58-65
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2021488365
Cited by
290
References
24
FWCI
13.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cardiac Resynchronization Therapy (and Multisite Pacing) in Pediatrics and Congenital Heart Disease: Five Years Experience in a Single Institution. https://app.cochat.ai/papers/10.1111/j.1540-8167.2008.01274.x
The paper
CECCHIN, F., FRANGINI, P. A., BROWN, D. W., FYNN‐THOMPSON, F., ALEXANDER, M. E., TRIEDMAN, J. K., GAUVREAU, K., WALSH, E. P., & BERUL, C. I. (2009). Cardiac Resynchronization Therapy (and Multisite Pacing) in Pediatrics and Congenital Heart Disease: Five Years Experience in a Single Institution. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2008.01274.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.