Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 175

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Does Left Atrial Volume and Pulmonary Venous Anatomy Predict the Outcome of Catheter Ablation of Atrial Fibrillation?

HOF, IRENE, CHILUKURI, KARUNA, ARBAB‐ZADEH, ARMIN, SCHERR, DANIEL, DALAL, DARSHAN, NAZARIAN, SAMAN, HENRIKSON, CHARLES, SPRAGG, DAVID, BERGER, RONALD, MARINE, JOSEPH, CALKINS, HUGH · 2009 · Journal of Cardiovascular Electrophysiology

Abstract

Introduction: Preprocedural factors may be helpful in selecting patients with atrial fibrillation (AF) for treatment with catheter ablation and in making an assumption regarding their prognosis. The aims of this study were to investigate whether left atrial (LA) volume and pulmonary venous (PV) anatomy, evaluated by computed tomography (CT) prior to ablation, will predict AF recurrence following catheter ablation. Methods and Results: We included 146 patients (mean age 57 ± 11 years, 83% male) with symptomatic AF (55% paroxysmal, 18% persistent, 27% long‐standing persistent). All patients underwent CT scanning prior to catheter ablation to evaluate LA volume and PV anatomy. Circumferential PV isolation was performed guided by Cartomerge electroanatomical mapping. The outcome was defined as complete success, improvement, or failure. After a mean follow‐up of 19 ±7 months, complete success was achieved in 59 patients (40%), and 38 patients (26%) demonstrated improvement. LA volume was found to be an independent predictor of AF recurrence with an adjusted OR of 1.14 for every 10‐mL increase in volume (95% CI 1.00–1.29, P = 0.047). PV variations were equally distributed among the different outcomes of the ablation procedure, and therefore univariate analysis did not identify PV anatomy as a predictor of outcome. Conclusion: LA volume is an independent predictor of AF recurrence after catheter ablation. Additionally, PV anatomy did not have any effect on the outcome. These findings suggest that an assessment of LA volume may be incorporated into the preprocedural evaluation of patients being considered for AF ablation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.2009.01504.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 175

Metadata

Authors
HOF, I., CHILUKURI, K., ARBAB‐ZADEH, A., SCHERR, D., DALAL, D., NAZARIAN, S., HENRIKSON, C., SPRAGG, D., BERGER, R., MARINE, J., & CALKINS, H.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2009-08-26
Volume
20
Issue
9
Pages
1005-1010
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2155661608
Cited by
175
References
2
FWCI
10.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Does Left Atrial Volume and Pulmonary Venous Anatomy Predict the Outcome of Catheter Ablation of Atrial Fibrillation? https://app.cochat.ai/papers/10.1111/j.1540-8167.2009.01504.x
The paper
HOF, I., CHILUKURI, K., ARBAB‐ZADEH, A., SCHERR, D., DALAL, D., NAZARIAN, S., HENRIKSON, C., SPRAGG, D., BERGER, R., MARINE, J., & CALKINS, H. (2009). Does Left Atrial Volume and Pulmonary Venous Anatomy Predict the Outcome of Catheter Ablation of Atrial Fibrillation? Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2009.01504.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.