CoChat

Safety and Convenience of Continuous Warfarin Strategy During the Periprocedural Period in Patients Who Underwent Catheter Ablation of Atrial Fibrillation

Open access
KWAK, JAE‐JIN, PAK, HUI‐NAM, JANG, JIN‐KUN, KIM, SOOK KYOUNG, PARK, JAE HYUNG, CHOI, JONG‐IL, HWANG, CHUN, KIM, YOUNG‐HOON · 2010 · Journal of Cardiovascular Electrophysiology
Cited by 71

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Continuous Warfarin Before AF Ablation. Background: We investigated the efficiency and convenience of a continuous warfarinization (CW) strategy during the periprocedural period of radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF) in comparison with the classic strategy of switching to heparin (SH). Methods and Results: We compared CW (n = 49) and SH (n = 55, 3 days before RFCA) in 104 patients who underwent RFCA of AF (77 males, 55 ± 12 years old, paroxysmal AF: persistent AF = 63:41). During the procedure, the activated clotting time (ACT) was maintained between 350 and 400 seconds, and a requirement of H, postablation INR, and periprocedural complications were compared. Results were as follows: (1) in the CW group, the preprocedural INR (1.85 ± 0.61 vs 1.05 ± 0.12, P < 0.001) and the proportions of INR > 2.0 after RFCA (1st postprocedure day 61.2% vs 5.5%, P < 0.001; 2nd postprocedure day 83.3% vs 21.8%, P < 0.005) were higher, and the heparin requirement was lower (2012 ± 998 U/30 minutes vs 2921 ± 795 U/30 minutes, P < 0.001) than in the SH group. (2) The incidences of hemorrhagic complications (18.2% vs 18.4%, P = NS) or the major bleeding rates (reduced hemoglobin ≥ 4 g/dL, requiring blood transfusion; 3.6% vs 12.2%, P = NS) were not significantly different in the CW group than in the SH group. Conclusion: The periprocedural CW strategy maintains a more stable INR immediately after AF ablation without increasing hemorrhagic complications compared with the classic strategy of SH. Simple CW can replace SH in an experienced laboratory with a low risk of hemopericardium during AF ablation. (J Cardiovasc Electrophysiol, Vol. 21, pp. 620‐625, June 2010)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.2009.01670.x

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 71

Metadata

Authors
KWAK, J., PAK, H., JANG, J., KIM, S. K., PARK, J. H., CHOI, J., HWANG, C., & KIM, Y.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2010-05-17
Volume
21
Issue
6
Pages
620-625
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2095306612
Cited by
71
References
5
FWCI
4.35
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Safety and Convenience of Continuous Warfarin Strategy During the Periprocedural Period in Patients Who Underwent Catheter Ablation of Atrial Fibrillation. https://app.cochat.ai/papers/10.1111/j.1540-8167.2009.01670.x
The paper
KWAK, J., PAK, H., JANG, J., KIM, S. K., PARK, J. H., CHOI, J., HWANG, C., & KIM, Y. (2010). Safety and Convenience of Continuous Warfarin Strategy During the Periprocedural Period in Patients Who Underwent Catheter Ablation of Atrial Fibrillation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2009.01670.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.