The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Device‐Related Infection Among Patients With Pacemakers and Implantable Defibrillators: Incidence, Risk Factors, and Consequences
Abstract
Risk Factors and Complications of Pacemaker and ICD Infection. Background: Device‐related infection is a major limitation of device therapy for cardiac arrhythmia. Methods: The authors analyzed the incidence and risk factors for cardiac device infection (CDI) among consecutive patients implanted with pacemaker (PM) or implantable cardioverter defibrillator (ICD) (including cardiac resynchronization therapy devices) at a tertiary health center in Hamilton, Ontario, Canada. Most patients with device‐related infections were identified by an internal infection control system that reports any positive wound and blood cultures following surgery, between 2005 and the present. A retrospective review of patient records was also performed for all patients who received an ICD or PM between July 1, 2003 and March 20, 2007. Results: A total of 24 infections were identified among 2,417 patients having device surgery (1%). Fifteen of these infections (60%) were diagnosed within 90 days of the last surgical procedure. Univariate analysis showed that patients presenting with CDI were more likely to have had a device replacement, rather than a new implant, had more complex devices (dual/triple chamber vs single), and were more likely to have had a prior lead dislodgement. Multivariate analysis found device replacement (P = 0.02) and cardiac resynchronization therapy (CRT)/dual‐chamber devices (P = 0.048) to be independent predictors of infection. One patient developed septic pulmonary emboli after having laser‐assisted lead extraction. No patient died and 22 patients received a new device. Conclusion: CDI occurs in about 1% of cases in high volume facilities. Pulse generator replacement surgery and dual‐ or triple‐chamber device implantation were associated with a significantly increased risk of infection. (J Cardiovasc Electrophysiol, Vol. pp. 786‐790, July 2010)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., Carson, P., DiCarlo, L., DeMets, D., White, B. G., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032423 · Cited by 5,812
Systemic Infection Related to Endocarditis on Pacemaker Leads: Clinical Presentation and Management
Klug, D., Lacroix, D., Savoye, C., Goullard, L., Grandmougin, D., Hennequin, J. L., Kacet, S., & Lekieffre, J. (1997) · Circulation · doi:10.1161/01.cir.95.8.2098 · Cited by 593
Cited by
Tong, S. Y. C., Davis, J. S., Eichenberger, E., Holland, T. L., & Fowler, V. G. (2015) · Clinical Microbiology Reviews · doi:10.1128/cmr.00134-14 · Cited by 5,192
Greenspon, A. J., Patel, J. D., Lau, E., Ochoa, J. A., Frisch, D. R., Ho, R. T., Pavri, B. B., & Kurtz, S. M. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.04.033 · Cited by 780
Polyzos, K. A., Konstantelias, A. A., & Falagas, M. E. (2015) · EP Europace · doi:10.1093/europace/euv053 · Cited by 493
Sandoe, J. A. T., Barlow, G., Chambers, J. B., Gammage, M., Guleri, A., Howard, P., Olson, E., Perry, J. D., Prendergast, B. D., Spry, M. J., et al. (2015) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dku383 · Cited by 403
Tao, H., Hwang, S.-W., Marelli, B., An, B., Moreau, J. E., Yang, M., Brenckle, M. A., Kim, S., Kaplan, D. L., Rogers, J. A., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1407743111 · Cited by 337
Metadata
- Authors
- NERY, P. B., FERNANDES, R., NAIR, G. M., SUMNER, G. L., RIBAS, C. S., MENON, S. M. D., WANG, X., KRAHN, A. D., MORILLO, C. A., CONNOLLY, S. J., & HEALEY, J. S.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2010-06-25
- Volume
- 21
- Issue
- 7
- Pages
- 786-790
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2109969037
- Cited by
- 188
- References
- 2
- FWCI
- 11.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Device‐Related Infection Among Patients With Pacemakers and Implantable Defibrillators: Incidence, Risk Factors, and Consequences. https://app.cochat.ai/papers/10.1111/j.1540-8167.2009.01690.x
- The paper
- NERY, P. B., FERNANDES, R., NAIR, G. M., SUMNER, G. L., RIBAS, C. S., MENON, S. M. D., WANG, X., KRAHN, A. D., MORILLO, C. A., CONNOLLY, S. J., & HEALEY, J. S. (2010). Device‐Related Infection Among Patients With Pacemakers and Implantable Defibrillators: Incidence, Risk Factors, and Consequences. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2009.01690.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.