CoChat

Ablation of Severe Drug‐Resistant Tachyarrhythmia During Pregnancy

SZUMOWSKI, LUKASZ, SZUFLADOWICZ, EWA, ORCZYKOWSKI, MICHAŁ, BODALSKI, ROBERT, DEREJKO, PAWEŁ, PRZYBYLSKI, ANDRZEJ, URBANEK, PIOTR, KUŚMIERCZYK, MARIUSZ, KOŹLUK, EDWARD, SACHER, FREDERIC, SANDERS, PRASHANTHAN, DANGEL, JOANNA, HAISSAGUERRE, MICHEL, WALCZAK, FRANCISZEK · 2010 · Journal of Cardiovascular Electrophysiology
Cited by 101

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Ablation of Tachyarrhythmia During Pregnancy. Aims: The goal of this study was to describe mapping and ablation of severe arrhythmias during pregnancy, with minimum or no X‐ray exposure. Treatment of tachyarrhythmia in pregnancy is a clinical problem. Pharmacotherapy entails a risk of adverse effects and is unsuccessful in some patients. Radiofrequency ablation has been performed rarely, because of fetal X‐ray exposure and potential maternal and fetus complications. Group and Method: Mapping and ablation was performed in 9 women (age 24–34 years) at 12–38th week of pregnancy. Three had permanent junctional reciprocating tachycardia, and 2 had incessant atrial tachycardia. Four of them had left ventricular ejection fraction ≤45%. One patient had atrioventricular nodal reciprocating tachycardia requiring cardioversion. Three patients had Wolff‐Parkinson‐White syndrome. Two of them had atrial fibrillation with ventricular rate 300 bpm and 1 had atrioventricular tachycardia 300 bpm. Fetal echocardiography was performed before and after the procedure. Results: Three women had an electroanatomic map and ablation done without X‐ray exposure. The mean fluoroscopy time in the whole group was 42 ± 37 seconds. The mean procedure time was 56 ± 18 minutes. After the procedure, all women and fetuses were in good condition. After a mean period of 43 ± 23 months follow up (FU), all patients were free of arrhythmia without complications related to ablation either in the mothers or children. Conclusion: Ablation can be performed safely with no or minimal radiation exposure during pregnancy. In the setting of malignant, drug‐resistant arrhythmia, ablation may be considered a therapeutic option in selected cases. (J Cardiovasc Electrophysiol, Vol. 21, pp. 877‐882, August 2010)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.2010.01727.x

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 101

Metadata

Authors
SZUMOWSKI, L., SZUFLADOWICZ, E., ORCZYKOWSKI, M., BODALSKI, R., DEREJKO, P., PRZYBYLSKI, A., URBANEK, P., KUŚMIERCZYK, M., KOŹLUK, E., SACHER, F., SANDERS, P., DANGEL, J., HAISSAGUERRE, M., & WALCZAK, F.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2010-08
Volume
21
Issue
8
Pages
877-882
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2051338626
Cited by
101
References
4
FWCI
3.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ablation of Severe Drug‐Resistant Tachyarrhythmia During Pregnancy. https://app.cochat.ai/papers/10.1111/j.1540-8167.2010.01727.x
The paper
SZUMOWSKI, L., SZUFLADOWICZ, E., ORCZYKOWSKI, M., BODALSKI, R., DEREJKO, P., PRZYBYLSKI, A., URBANEK, P., KUŚMIERCZYK, M., KOŹLUK, E., SACHER, F., SANDERS, P., DANGEL, J., HAISSAGUERRE, M., & WALCZAK, F. (2010). Ablation of Severe Drug‐Resistant Tachyarrhythmia During Pregnancy. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2010.01727.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.