Catheter Ablation of Long‐Standing Persistent Atrial Fibrillation: A Lesson from Circumferential Pulmonary Vein Isolation
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Catheter Ablation of Long‐Standing Persistent AF. Introduction: Circumferential pulmonary vein isolation (CPVI) is associated with a high success rate in patients with paroxysmal and persistent atrial fibrillation (AF). However, in patients with long‐standing persistent AF, the ideal ablation strategy still remains a matter of debate. Methods and Results: Two‐hundred and five patients underwent catheter ablation for long‐standing persistent AF defined as continuous AF of more than 1‐year duration. In a first step, all patients underwent CPVI. If direct‐current cardioversion failed following CPVI, ablation of complex fractionated atrial electrograms (CFAEs) was performed. The goal was conversion into sinus rhythm (SR) or, alternatively, atrial tachycardia (AT) with subsequent ablation. A total of 340 procedures were performed. CPVI alone was performed during 165 procedures in 124 of 205 (60.5%) patients. In the remaining 81 patients, additional CFAE ablation was performed in 45, left linear lesions for recurrent ATs in 44 and SVC isolation in 15 patients, respectively, resulting in inadvertent left atrial appendage isolation in 9 (4.4%) patients. After the initial ablation procedure, 67 of 199 patients remained in SR during a mean follow‐up of 19 ± 11 months. Six patients were lost to follow‐up. After a mean of 1.7 ± 0.8 procedures, 135 of 199 patients (67.8%) remained in SR. Eighty‐six patients (43.2%) remained in SR following CPVI performed as the sole ablative strategy. Conclusions: CPVI alone is sufficient to restore SR in 43.2% of patients with long‐standing persistent AF. Multiple procedures and additional ablation strategies with a significant risk of inadvertent left atrial appendage isolation are often required to maintain stable SR. (J Cardiovasc Electrophysiol, Vol. 21, pp. 1085‐1093)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pappone, C., Rosanio, S., Augello, G., Gallus, G., Vicedomini, G., Mazzone, P., Gulletta, S., Gugliotta, F., Pappone, A., Santinelli, V., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00577-1 · Cited by 781
Cited by
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Catheter Ablation of Long-Standing Persistent Atrial Fibrillation
Tilz, R. R., Rillig, A., Thum, A.-M., Arya, A., Wohlmuth, P., Metzner, A., Mathew, S., Yoshiga, Y., Wissner, E., Kuck, K.-H., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.04.060 · Cited by 469
Self-citationPulmonary Vein Isolation Versus Defragmentation
Vogler, J., Willems, S., Sultan, A., Schreiber, D., Lüker, J., Servatius, H., Schäffer, B., Moser, J., Hoffmann, B. A., & Steven, D. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.09.088 · Cited by 349
Metadata
- Authors
- TILZ, R. R., CHUN, K. R. J., SCHMIDT, B., FUERNKRANZ, A., WISSNER, E., KOESTER, I., BAENSCH, D., BOCZOR, S., KOEKTUERK, B., METZNER, A., ZERM, T., ERNST, S., ANTZ, M., KUCK, K., & OUYANG, F.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2010-05-07
- Volume
- 21
- Issue
- 10
- Pages
- 1085-1093
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2080081967
- Cited by
- 114
- References
- 1
- FWCI
- 10.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.