CoChat

Low Risk of Major Complications Associated With Pulmonary Vein Antral Isolation for Atrial Fibrillation: Results of 500 Consecutive Ablation Procedures in Patients With Low Prevalence of Structural Heart Disease From a Single Center

LEE, GEOFFREY, SPARKS, PAUL B., MORTON, JOSEPH B., KISTLER, PETER M., VOHRA, JITENDRA K., MEDI, CAROLINE, ROSSO, RAPHAEL, TEH, ANDREW, HALLORAN, KAREN, KALMAN, JONATHAN M. · 2010 · Journal of Cardiovascular Electrophysiology
Cited by 101

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: To report the major complication rate associated with pulmonary vein antral isolation (PVAI) in a consecutive series of 500 patients from a single center. BACKGROUND: Catheter ablation for atrial fibrillation (AF) is an established procedure for refractory AF. However, the risk of major complications has been reported to range from 3.9% to 4.5% and continues to represent a cause for concern. We hypothesized that these studies may have overestimated the rate of major complications associated with PVAI in patients with a low prevalence of structural heart disease (SHD). METHODS: Data were prospectively collected from 500 consecutive AF ablation procedures on 424 patients (mean age 55 ± 11 years, 79% men, paroxysmal AF-80% and persistent AF-20%, CHADS₂ scores of 0, 1, 2, 3 present in 64%, 28%, 7%, 1%, respectively), performed between July 2006 and September 2009. All procedures were performed under general anesthesia with intraoperative transesophageal echo. PVAI was performed using a nonfluoroscopic mapping system with an endpoint of PV isolation. Adjunctive left atrial ablation was performed in 21% of patients only. Major complications were defined from a compilation of those reported in 5 prior studies reporting complications. RESULTS: In 500 procedures, there were no instances of death, stroke/TIA, cardiac tamponade, atrioesophageal fistula, or PV stenosis. Major complications occurred in 4 procedures (0.8%): esophageal hematoma (TEE probe)--2; pharyngeal trauma--1; and retroperitoneal hematoma-1. CONCLUSIONS: AF ablation can be performed safely in young patients without structural heart disease with a low risk (<1%) of major complications when using a strategy of PVAI.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8167.2010.01870.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 101

Metadata

Authors
LEE, G., SPARKS, P. B., MORTON, J. B., KISTLER, P. M., VOHRA, J. K., MEDI, C., ROSSO, R., TEH, A., HALLORAN, K., & KALMAN, J. M.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2010-08-19
Volume
22
Issue
2
Pages
no-no
ISSN
1045-3873 (ISSN-L)
OpenAlex
W1988363095
Cited by
101
References
2
FWCI
7.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Low Risk of Major Complications Associated With Pulmonary Vein Antral Isolation for Atrial Fibrillation: Results of 500 Consecutive Ablation Procedures in Patients With Low Prevalence of Structural Heart Disease From a Single Center. https://app.cochat.ai/papers/10.1111/j.1540-8167.2010.01870.x
The paper
LEE, G., SPARKS, P. B., MORTON, J. B., KISTLER, P. M., VOHRA, J. K., MEDI, C., ROSSO, R., TEH, A., HALLORAN, K., & KALMAN, J. M. (2010). Low Risk of Major Complications Associated With Pulmonary Vein Antral Isolation for Atrial Fibrillation: Results of 500 Consecutive Ablation Procedures in Patients With Low Prevalence of Structural Heart Disease From a Single Center. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/j.1540-8167.2010.01870.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.